Cummins/Onan — Configuring the Controller Using Control Switch
Adjustments · genset controller
From a Cummins/Onan service manual — check it applies to your exact model before use.
Applies to: Cummins/Onan MDKB, Cummins/Onan MDKBH
Before you start
- In configuration mode the control will not start, prime or display faults.
Procedure
- Remove the insulating connectors from harness connectors CONFIG 1 and CONFIG 2 and connect them together.
- Press START to increase the code number or STOP to decrease it one unit each press.
- Set the configuration code number to 19 for this genset.
- Verify the status lamp blinks one blink, pause, then nine blinks.
- Disconnect CONFIG 1 from CONFIG 2 and re-install the insulating connectors.
Specs & values
- Configuration code number for this genset is 19
Full service-parts list: Cummins/Onan MDKB →, Cummins/Onan MDKBH →