Home›Repair guides›Cummins/Onan›Charging the High Pressure Side with Liquid R-134a

Cummins/Onan — Charging the High Pressure Side with Liquid R-134a

Maintenance · AC system

From a Cummins/Onan service manual covering: ES2075s, FS1870s, M11979s, M1976s, M1977s, M1978s. Check it applies to your exact model before use.

Applies to: Kubota 2482B engine

Before you start

  • Do not operate the power unit engine. No more than one pound of refrigerant should be added at this time.
  • Adding R-134a as a liquid can damage the compressor if not done correctly.

Procedure

  1. Connect the center service hose from the gauge set to the R-134a container dispensing valve.
  2. Purge the hose of any air using R-134a gas pressure from the container.
  3. Turn the refrigerant container upside down.
  4. Open the R-134a dispensing valve and HP side hand valve on the gauge set to flow liquid R-134a into the system.
  5. When approximately one pound of R-134a liquid has been added, close the R-134a supply.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.