Home›Repair guides›Cummins/Onan›Changing Generator Set Frequency

Cummins/Onan — Changing Generator Set Frequency

Adjustments · Control box frequency selection jumpers

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan MDKB, Cummins/Onan MDKBH, Kubota Z482 engine

Before you start

  • When changing frequency, make sure the line circuit breakers are suitable for the new output.

Procedure

  1. Remove the control box cover.
  2. Connect J5 to P6 for 60 Hz.
  3. Disconnect J5 from P7 for 50 Hz.
  4. Apply the appropriate reconfiguration label.
  5. Replace the control box cover.
  6. Check and adjust voltage as necessary after the frequency has been changed.

Specs & values

  • J5 to P6 = 60 Hz
  • J5 from P7 disconnected = 50 Hz

Full service-parts list: Cummins/Onan MDKB →, Cummins/Onan MDKBH →, Kubota Z482 engine →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.