Home›Repair guides›Cummins/Onan›Battery connection

Cummins/Onan — Battery connection

Installation

From a Cummins/Onan owner's manual covering: 10CW-150R, LOCW-150 R/, LOCW-3R/12 F. Check it applies to your exact model before use.

Applies to: Cummins/Onan 10CW-150R, Cummins/Onan Spec A, Cummins/Onan Spec B, Cummins/Onan Spec C, Cummins/Onan Spec D, Cummins/Onan Spec E, Cummins/Onan Spec F, Cummins/Onan Spec G

Before you start

  • Do not reverse the connections.

Procedure

  1. For electric starting, use two 6-volt batteries in series or one 12-volt battery.
  2. Connect positive post of one battery to negative post of the second for series 12 volts.
  3. Connect remaining battery terminals to proper terminals in generator terminal box.
  4. Observe correct polarity; do not reverse connections.
  5. Above 90°F continuous operation may require reduced battery specific gravity.

Specs & values

  • 12 volts
  • two 6-volt batteries in series

Full service-parts list: Cummins/Onan 10CW-150R →, Cummins/Onan Spec A →, Cummins/Onan Spec B →, Cummins/Onan Spec C →, Cummins/Onan Spec D →, Cummins/Onan Spec E →, Cummins/Onan Spec F →, Cummins/Onan Spec G →

Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.