Home›Repair guides›Cummins/Onan›Battery Checkout (A)

Cummins/Onan — Battery Checkout (A)

Maintenance

From a Cummins/Onan service manual covering: DL4, DL6, DL6T. Check it applies to your exact model before use.

Applies to: Cummins/Onan DL4, Cummins/Onan DL6, Cummins/Onan DL6T

Procedure

  1. Check charge condition of the battery with a hydrometer.
  2. Electrolyte specific gravity should be about 1.260 for a fully charged battery at 80 deg F (27 deg C).
  3. If not, add approved water to keep electrolyte at proper level and recharge the battery.
  4. If battery will not recharge, replace it.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Specific gravity about 1.260 at 80 deg F (27 deg C)

Full service-parts list: Cummins/Onan DL6 →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.