Home›Repair guides›Cummins/Onan›Out-Of-Service Protection (Storage longer than 30 days)

Cummins/Onan 80MDKAL11454B — Out-Of-Service Protection (Storage longer than 30 days)

Maintenance · generator set

For the Cummins/Onan 80MDKAL11454B, from the Cummins/Onan operator's manual.

Applies to: Cummins/Onan MDKAL, Kubota D1005 engine

Before you start

  • Battery electrolyte can cause severe eye damage and burns to the skin.
  • Anti-freeze is toxic and can pollute the environment; dispose according to local regulations for hazardous substances.

Procedure

  1. Exercise the genset until the engine is at operating temperature.
  2. Shut down the genset and disconnect the battery cables (negative [-] cable first); store the battery in a cool, dry place and connect to a trickle charger once every 30 days.
  3. Drain the crankcase oil while still warm; replace oil filter; refill crankcase and attach a tag indicating oil viscosity.
  4. Check the coolant level; add coolant if low; test the coolant mixture if freezing temperatures are possible.
  5. Drain the sea water cooling system or protect it with a 50-50 anti-freeze mixture: close the sea cock, remove the sea water inlet hose at the filter, place the hose end in a bucket of anti-freeze and
  6. Plug exhaust outlets to prevent entrance of moisture, bugs, dirt, etc.
  7. Clean and wipe the entire genset; lightly coat parts that may rust with grease or oil.

Specs & values

  • No. 2 diesel fuel lubricating qualities protect cylinders at least 30 days

Full service-parts list: Cummins/Onan MDKAL →, Kubota D1005 engine →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.