Home›Repair guides›Cummins/Onan›Starting the Plant Electrically

Cummins/Onan 6GO — Starting the Plant Electrically

Operation · Starting system

For the Cummins/Onan 6GO, from the Cummins/Onan operator's manual.

Applies to: Continental Red Seal Y91-273 or Y91-264 engine

Before you start

  • Do not press the START button continuously.
  • Do not overprime.

Procedure

  1. See that the ignition switch is set at the ELEC. START position.
  2. For gasoline fuel, press the START button firmly for several seconds to fill the fuel pump and carburetor.
  3. Hold the start button in until the plant has reached running speed.
  4. If it does not start, press the START button for periods of not more than five seconds at a time with equivalent stops between.
  5. If the plant fails to start after a few attempts, check the fuel and ignition systems and repeat.
  6. For gas operation, lock the choke control arm down and see that the gasoline supply is turned off.
  7. Press the START button; the regulator primer button may have to be pushed the first time. Do not overprime.

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.