Cummins/Onan 627.20199 — Break-In Procedure
Maintenance · engine
For the Cummins/Onan 627.20199, from the Cummins/Onan owner's manual.
Applies to: Craftsman 627.20199
Before you start
- Before fifty operating hours, cylinder head bolts must be re-torqued to avoid blown gaskets.
Procedure
- One-half hour at 1/2 load.
- One-half hour at 3/4 load.
- Full load.
Specs & values
- Use SE/CC oil
Full service-parts list: Craftsman 627.20199 →
Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.