Home›Repair guides›Cummins/Onan›Storing the Genset

Cummins/Onan 4.0BGEFA261 OOL / 4.0BGEFA26100L — Storing the Genset

Maintenance

For the Cummins/Onan 4.0BGEFA261 OOL / 4.0BGEFA26100L, from the Cummins/Onan operator's manual.

Applies to: Cummins/Onan EM (SN5782U1G2RA) engine

Before you start

  • Gasoline preservatives (stabilizers) are toxic; follow container label instructions, avoid skin contact and wash hands with soap and water after dispensing.

Procedure

  1. Fill the fuel tank with fresh fuel and add a fuel preservative (OnaFresh™) per container label instructions.
  2. Run the genset about 10 minutes at approximately 1/2 rated power to fill fuel lines and carburetor with treated fuel.
  3. Turn off air conditioner and other large loads, push the genset line circuit breaker to OFF and stop the genset.
  4. Remove the air filter and restart the genset; spray an engine fogger (OnaGard™) into the carburetor and then stop the genset.
  5. Change the air filter element if it is dirty.
  6. Change the engine oil and attach a tag indicating its oil viscosity.
  7. Disconnect the battery cables (negative [-] cable first) and store the battery per battery manufacturer's recommendations.
  8. Plug the exhaust tail pipe to keep out dirt, moisture and bugs.
  9. Close the fuel supply valve (if so equipped).

Tools required

  • OnaFresh fuel preservative Amazon
  • OnaGard engine fogger Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Store if idle more than 120 days
  • Run about 10 minutes at approximately 1/2 rated power

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →