Cummins/Onan 4.0BGEFA261 OOL / 4.0BGEFA26100L — Break-In

Operation · Engine

For the Cummins/Onan 4.0BGEFA261 OOL / 4.0BGEFA26100L, from the Cummins/Onan operator's manual.

Applies to: Cummins/Onan EM (SN5782U1G2RA) engine

Procedure

  1. Run the genset at approximately 1/2 rated power for the first 2 hours.
  2. Then run at 3/4 rated power for 2 more hours.
  3. Check the engine oil and oil level; use proper oil for ambient temperatures.
  4. Check the oil level twice a day or every 4 hours during the first 24 hours of operation.
  5. Change the oil after the first 50 hours of operation.

Specs & values

  • 1/2 rated power for first 2 hours
  • 3/4 rated power for 2 more hours
  • Change oil after first 50 hours

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.