Before you start

  • Do not smoke while servicing batteries; explosive gases are emitted.

Procedure

  1. Check coolant level, add if necessary using recommended anti-freeze.
  2. Run set until thoroughly warm under at least 50 percent load; stop by shutting off fuel supply.
  3. Drain oil base while still warm; refill and attach a tag indicating viscosity of oil used.
  4. Remove spark plugs; pour 1 ounce rust inhibiting oil (or SAE #10 oil) into each cylinder; crank over several times; install spark plugs.
  5. Clean throttle and governor linkage; protect by wrapping with a clean cloth.
  6. Plug exhaust outlets to prevent entrance of moisture, bugs, dirt.
  7. Clean off dirt and dry entire unit; coat parts likely to rust with light film of oil or grease.
  8. Disconnect battery and follow standard battery storage procedure; apply nonconductive grease to cable terminal lugs.
  9. Fill fuel tank to prevent condensate contamination.
  10. Provide a suitable protective cover for the entire unit.
  11. Drain sea water cooling system.

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.