Home›Repair guides›Cummins/Onan›Entering Password

Cummins/Onan 1750DQKB / 3200 Series — Entering Password

Adjustments · Control panel

For the Cummins/Onan 1750DQKB / 3200 Series, from the Cummins/Onan service manual.

Applies to: Cummins/Onan 1750DQKB, Cummins/Onan DFE

Procedure

  1. Display submenu to modify.
  2. Press either the + or - button within the displayed submenu. The Password menu appears.
  3. Press the + and - buttons to select the first character of the password (A-Z or 0-9).
  4. Press the arrow button to select the next character field.
  5. Repeat steps 3 and 4 to enter remaining password characters.
  6. Press the Enter button after entering the password.
  7. After making desired changes to submenu, exit submenu to save changes.

Specs & values

  • Application password for Setup submenus; User password for Adjust submenu
  • Both passwords initially set to GENSET
  • Entered password is valid for 10 minutes after the last button is pressed

Full service-parts list: Cummins/Onan 1750DQKB →, Cummins/Onan DFE →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.