Home›Repair guides›Caterpillar›Test Step 11. Compare the Pressure or Temperature to the Actual Pressure or Temperature

Caterpillar — Test Step 11. Compare the Pressure or Temperature to the Actual Pressure or Temperature

Testing & diagnosis · Suspect temperature or pressure sensor

From a Caterpillar service manual covering: 3500B Engine, PM3516, PM3516 Power Module. Check it applies to your exact model before use.

Applies to: Caterpillar 3500B engine

Procedure

  1. Turn the ECS to the OFF/RESET position.
  2. For temperature sensors install a 6V-9130 Temperature Adapter near the sensor and observe the reading.
  3. For pressure sensors disconnect, remove the sensor, connect it to the sensor connector.
  4. Connect the vacuum pump test unit and differential pressure gauge.
  5. Turn the ECS ON, engine OFF, and observe the barometric pressure reading.
  6. Pull 5 kPa (0.7 psi) of vacuum and compare ET and test kit readings.

Tools required

  • 6V-9130 Temperature Adapter Amazon
  • Vacuum pump test unit Amazon
  • Differential pressure gauge Amazon
  • ET (Electronic Technician) Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • ET should show a 5 ± 2 kPa (0.7 ± 0.3 psi) drop in pressure
  • Temperature can vary 15 °C (59 °F) when below 0 °C (32 °F)

Source: Caterpillar service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.