Home›Repair guides›Caterpillar›Adjustments for Generators in Parallel Operation

Caterpillar — Adjustments for Generators in Parallel Operation

Adjustments · Voltage regulator R448

From a Caterpillar owner's manual covering: 3456, C1G1-Up, C2T1-Up, C3G1-Up, C4G1-Up, SR4B. Check it applies to your exact model before use.

Applies to: Caterpillar SR4B

Procedure

  1. Connect current transformer to S1 and S2 of J2.
  2. Set P1 quadrature droop to center.
  3. Apply rated load; voltage should drop 2 to 3%.
  4. Set no-load voltages identical for all generators.
  5. Connect generators in parallel and adjust speed for 0 kW exchange.
  6. Minimize circulating currents with P2 or Rhe.
  7. Apply available load; equalize kW by altering speed.
  8. Alter P1 to equalize currents.

Specs & values

  • Voltage drop 2% to 3%

Full service-parts list: Caterpillar SR4B →

Source: Caterpillar owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.