Before you start

  • Do not start the engine during the test
  • Ensure the engine control is in the OFF position

Procedure

  1. Ensure both air shutoff gates are latched OPEN and both switches connected.
  2. With power ON, activate EMERGENCY STOP; both gates should close.
  3. Latch only the right side gate; power ON; right gate should close.
  4. Latch only the left side gate; power ON; left gate should close.
  5. Reset both air shutoffs and operate the engine normally.

Full service-parts list: Caterpillar 3512 →, Caterpillar 3512B engine →

Source: Caterpillar owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.