Caterpillar 3054C — Cooling System Coolant (ELC) - Change
Maintenance
For the Caterpillar 3054C, from the Caterpillar owner's manual.
Applies to: Caterpillar 3054C engine
Before you start
- Pressurized system: hot coolant can cause serious burns.
Procedure
- Stop the engine, allow it to cool, loosen the filler cap slowly, and remove it.
- Open the drain valve or remove the drain plugs and allow the coolant to drain.
- Flush the cooling system with clean water and drain.
- Close the drain valve, clean and install the drain plugs.
- Fill with clean water, install the filler cap, and run until 49 to 66 °C (120 to 150 °F).
- Stop the engine, drain, and flush with clean water.
- Fill with Extended Life Coolant (ELC); do not install the filler cap.
- Run the engine at low idle for 5 minutes, then at high idle for one minute.
- Check the coolant level within 13 mm (0.5 inch) below the bottom of the fill pipe.
- Clean the filler cap and inspect the gasket; pressure test with a 9S-8140 Pressurizing Pump.
Tools required
- 9S-8140 Pressurizing Pump Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- 49 to 66 °C (120 to 150 °F)
- Fill no faster than 19 L (5 US gal) per minute
Full service-parts list: Caterpillar 3054C engine →
Source: Caterpillar owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.