Home›Repair guides›Caterpillar›Cooling System Coolant (DEAC) - Change

Caterpillar 3054C — Cooling System Coolant (DEAC) - Change

Maintenance

For the Caterpillar 3054C, from the Caterpillar owner's manual.

Applies to: Caterpillar 3054C engine

Before you start

  • Pressurized system: hot coolant can cause serious burns.

Procedure

  1. Stop the engine, allow it to cool, loosen the filler cap slowly, and remove it.
  2. Open the cooling system drain valve or remove a drain plug; allow the coolant to drain.
  3. Flush the cooling system with clean water to remove debris.
  4. Close the drain valve, clean and install the drain plugs.
  5. Fill with clean water and Caterpillar Fast Acting Cooling System Cleaner (0.5 L per 15 L).
  6. Start and run the engine at low idle for at least 30 minutes at 82 °C (180 °F).
  7. Stop the engine, drain, and flush with clean water until all cleaning agent is gone.
  8. Fill the cooling system with coolant/antifreeze.
  9. Run the engine at low idle, increase to 1500 rpm, and run at high idle for one minute.
  10. Check the coolant level within 13 mm (0.5 inch) below the bottom of the fill pipe.
  11. Clean and inspect the filler cap gasket; pressure test with a 9S-8140 Pressurizing Pump.

Tools required

  • 9S-8140 Pressurizing Pump Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 0.5 L (1 pint) cleaner per 15 L (4 US gal)
  • 82 °C (180 °F)
  • 1500 rpm
  • Fill no faster than 19 L (5 US gal) per minute

Full service-parts list: Caterpillar 3054C engine →

Source: Caterpillar owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.