Home›Repair guides›Baldor›LP Gas Connections (vapor withdrawal only)

Baldor — LP Gas Connections (vapor withdrawal only)

Installation · Gaseous fuel supply - LPG

From a Baldor service manual covering: GLC100, GLC125, GLC30, GLC35, GLC45, GLC50, GLC60, GLC80, MN2408. Check it applies to your exact model before use.

Applies to: Baldor (Baldor Generators / Baldor Electric Company) GLC100, Baldor (Baldor Generators / Baldor Electric Company) GLC80

Before you start

  • LPG and natural gas fuels are flammable and can cause fire, explosion, injury or death

Procedure

  1. Connect proper size gas pipe at the input to the LP Gas regulator.
  2. Use correct pipe size per Table 3-6 for flow rate and pipe length.
  3. Ensure all connections are sealed and no leaks are present.
  4. Verify fuel supply pressure is 11 inches water column (6 oz pressure).

Tools required

  • soap solution for leak check Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 11 inches water column (6 oz pressure)

Full service-parts list: Baldor (Baldor Generators / Baldor Electric Company) GLC100 →, Baldor (Baldor Generators / Baldor Electric Company) GLC80 →

Source: Baldor service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.