| 120/208 | 3 | Three phase | RD015, RD020, RD030, RD050 | |
| 120/208 | 3-phase | Stator power winding connections - 3-phase (Y) | 6 | Rated voltage between circuit breaker terminals E1-E2, E1-E3 and E2-E3 is 208V; terminal to neutral 120V |
| 120/208 | 3-phase | Y | 6-lead | Figure 7.3 - Stator Power Winding Connections. Rated 208V L-L, 120V L-N. |
| 120/208V | 3 | 3-phase alternator, "Y" configuration, 6 lead | 6 | Rated voltage between circuit breaker terminals E1-E2, E1-E3, E2-E3; rated voltage to neutral 120V |
| 120/208V | 3 | Stator power winding connections - 3-phase, Y configuration | 6 | Rated voltage between circuit breaker terminals E1-E2, E1-E3 and E2-E3 is 208V; between each terminal and neutral 00 is 120V |
| 120/208V | 3 | Y | 6 | Stator power winding connections (Figure 7.3) |
| 120/208V | 3 | Y (wye) - Stator Power Winding Connections, 3-phase, 120/208V | 6 lead (S1-S6, E1-E3, neutral 00) | Rated voltage between circuit breaker terminals E1-E2, E1-E3 and E2-E3 is 208V; between each terminal and neutral point 00 is 120V. 85 Amps, CB size 100. |
| 120/208V | 3 | Y configuration (6 lead) | 6 | Rated voltage between breaker terminals E1-E2, E1-E3, E2-E3 is 208V; between each terminal and neutral 00 is 120V. Voltage code G. |
| 120/208V | 3-phase | Y configuration, 6 lead | 6 | Rated voltage between circuit breaker terminals E1-E2, E1-E3 and E2-E3 is 208V; between each terminal and neutral point 00 is 120V |
| 120/240 | 1 | Single phase | RD015, RD020, RD030, RD048 | |
| 120/240 | 1-phase | 4-lead single-phase stator, connected at factory to main circuit breaker (voltage code A) | 4 | Rated voltage between circuit breaker terminals 240V; between each terminal and neutral 120V |
| 120/240 | 1-phase | Four-lead, single-phase stator - connected at the factory to the main circuit breaker (voltage code A) | 4-lead | Rated 240V between circuit breaker terminals; 120V between each terminal and neutral point 00. 60 Hz. |
| 120/240 | 3 | Three phase | RD015, RD020, RD030, RD048, RD050 | |
| 120/240V | 1 | 4-lead, single-phase stator; factory connected to main circuit breaker | 4 | Rated voltage between each circuit breaker terminal is 240V; between each terminal and neutral point 00 is 120V. Voltage code A. |
| 120/240V | 1 | Four-lead, single-phase stator (voltage code "A") | 4-wire | Rated voltage between each circuit breaker terminal is 240V; between each circuit breaker terminal and neutral point 00 is 120V. 104 Amps, CB size 125. |
| 120/240V | 1 | Four-lead, single-phase stator; voltage code "A" | 4 | Rated 240V between each circuit breaker terminal; 120V between each terminal and neutral point 00 |
| 120/240V | 1 | Four-lead, single-phase stator; windings factory-connected to the main circuit breaker | 4 | Rated voltage between each circuit breaker terminal is 240V; between each terminal and neutral point 00 is 120V |
| 120/240V | 1 | Voltage code A; four-lead, single-phase stator; windings factory-connected to main circuit breaker | 4 | Rated voltage between circuit breaker terminals 240V; between each terminal and neutral 120V |
| 120/240V | 1-phase | Four-lead, single-phase stator, voltage code A; windings connected at factory to main circuit breaker | 4 | Rated voltage between each circuit breaker terminal is 240V; between each terminal and neutral point 00 is 120V |
| 208 | 3 | Stator power winding connections - 3-phase, 120/208V (6 lead), 'Y' configuration | 6 | Rated voltage between circuit breaker terminals E1-E2, E1-E3 and E2-E3 is 208V; between each terminal and neutral point 00 is 120V. Output table: 25 kW, 120/208V, 3-phase, 0.8 pf, 87 Amp, 100 Amp circuit breaker (3 pole, 240V). |
| 208 | 3-phase | Circuit breaker size table (Figure 1) | | KW 25, 208 3-phase, 100 Amps, lug size #4 to 1/0. |
| 208 (3 Ø) | 3 | Circuit breaker size 100 A; lug size #4 to 1/0 | | 25 kW |
| 208 3 Ø | 3-phase | Generator main line circuit breaker / lug size | | KW 20, Amps 80, Lug size #4 to 1/0 |
| 208V | 3 | Circuit breaker lug size #4 to 1/0 | | KW 20, Volts/Amps 208 3-phase, Circuit Breaker Size 80 |
| 208V / 3-phase | 3 | Circuit breaker 80A, lug size #4 to 1/0 | | 20 kW |
| 208V, 3-phase | 3 | Circuit breaker size 100 A, lug size #4 to 1/0 | | 25 kW / 208V / 100A |
| 240 | 1 | Four-lead, single-phase stator; windings factory connected to main circuit breaker (voltage code 'A', 240V, 1-phase, 60 Hz) | 4 | Rated voltage between each circuit breaker terminal is 240V; between each circuit breaker terminal and neutral point 00 is 120V. Output table: 25 kW, 120/240V, 1-phase, 1.0 pf, 104 Amp, 125 Amp circuit breaker (2 pole, 240V). |
| 240 | 1-phase | Circuit breaker size table (Figure 1) | | KW 25, 240 1-phase, 125 Amps, lug size #4 to 1/0. |
| 240 (1 Ø) | 1 | Circuit breaker size 125 A; lug size #4 to 1/0 | | 25 kW |
| 240 1 Ø | 1-phase | Generator main line circuit breaker / lug size | | KW 20, Amps 100, Lug size #4 to 1/0 |