Home›Tradewinds Power›Tradewinds Power TP150TP

Tradewinds Power TP150TP Generator Set

The Tradewinds Power TP150TP is a 150 kW (187.5 kVA) DIESEL standby generator set powered by a Perkins 1106D-E70TAG2 engine. It is available at 120/240 V, 120/208 V and 480/277 V, 3-phase, 60 Hz and rated 521 A. It holds about 16.5 L (4.4 gal) of oil and 21 L (5.5 gal) of coolant, with a maximum ambient rating of 29 °C. Starting uses Not specified group-Not specified battery at 12 V. The set measures Not specified×Not specified×Not specified mm (None×None×None in), weighs about Not specified kg (None lb) and produces 80 dBA at Not specified m. An integrated tank holds Not specified L (None gal), roughly Not specified hours of runtime. The same 1106D-E70TAG2 engine also powers generator sets from Perkins.

150 kW
Standby
7.01 L
Displacement
16.5 L
Oil capacity
1
Document types

Typical fuel consumption for 150–155 kW Diesel generators →

Compare with other 150–155 kW Diesel generators →

Specifications

FuelDIESEL
Frequency60.0 Hz
Standby power150 kW
Standby kVA187
Prime power135 kW
EmissionsEPA Tier 3
ControllerDGC-2020
Oil capacity16.5 L
AlternatorMarathon 4-pole, 12-wire brushless generator, single bearing
Voltage options120/240 V, 120/208 V, 480/277 V
Phase3
Rated current521 A
Power factor0.8
Circuit breaker521 A
Battery groupNot specified
Battery voltage12 V
Battery quantityNot specified
Coolant capacity21.0 L
Max ambient29 °C
Sound level80.0 dBA @ Not specified m
Tank runtimeNot specified hr

Engine

Perkins 1106D-E70TAG2
Oil capacity21.0 L
Coolant capacity21.0 L
Displacement7.01 L
AspirationDirect Injection
Rated speed1800 rpm

Filters for the Perkins 1106D-E70TAG2

5

Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.

SystemFilterDescriptionCross-references
Oil filterP550920Lube Filter, Spin-On Full FlowPERKINS 2654A111, PERKINS 4627133, NAPA 7325, BALDWIN B7378 KuduParts $45.00 FridayParts $46.80

Listed for this engine in only one kind of machine, so they may depend on how the engine was installed:

SystemFilterDescriptionCross-references
Fuel filterP502420Fuel Filter, CartridgePERKINS 2656F823, PERKINS 4415122, NAPA 600488, CLAAS 0011377510 buy
Fuel filterP550974Fuel Filter, In-LinePERKINS 102601, NAPA 3270, BLAW KNOX 0016481600, VERMEER 102995001 FridayParts $356.80
Fuel / water separatorP551425Fuel Filter, Water Separator CartridgePERKINS 26560139, PERKINS 26560141, NAPA 3586, BALDWIN BF7677-D FridayParts $20.00
Fuel / water separatorP551426Fuel Filter, Water Separator CartridgePERKINS 26560920, BALDWIN BF9830-D, SULLAIR 1006374, JCB 320A7128 KuduParts $34.00

Same engine, other brands

1 brand

The Perkins 1106D-E70TAG2 in this set also powers 2 generator sets sold under 1 other brand. Service parts and maintenance intervals for the engine are shared; enclosure, alternator, controller and ratings are not.

BrandModels
PerkinsLG114P, LK274E

Maintenance & consumables

for the Perkins 1106D-E70TAG2
ItemSpecCapacityPart #Interval
Air filter—
Fuel filter—
Oil filter—
Battery—
Belt—
Coolant21.0 L—
Oil21.0 L—
Spark plug—

Compatible filters for the Perkins 1106D-E70TAG2 — cross-referenced via Donaldson. Options to verify against your serial number, not confirmed for this exact unit.

  • Air filter: Donaldson P635904 Donaldson P635980 Baldwin PA3840

Common questions

How many kW is the Tradewinds Power TP150TP?

The Tradewinds Power TP150TP is rated 150 kW standby (187.5 kVA).

Which engine powers the Tradewinds Power TP150TP?

The Tradewinds Power TP150TP is powered by the Perkins 1106D-E70TAG2 engine.

Is the Tradewinds Power TP150TP diesel or gas?

The Tradewinds Power TP150TP runs on DIESEL.

What's the oil capacity on a Tradewinds Power TP150TP?

The Perkins 1106D-E70TAG2 engine in the Tradewinds Power TP150TP has an oil capacity of 21.0 liters.

What is the coolant capacity of the Tradewinds Power TP150TP?

The Tradewinds Power TP150TP cooling system holds 21 liters (5.5 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

What is the continuous rating of the Tradewinds Power TP150TP?

The Tradewinds Power TP150TP is rated 135 kW prime (168 kVA), against 150 kW standby.

How loud is the Tradewinds Power TP150TP?

The Tradewinds Power TP150TP is rated at 80.0 dBA at Not specified m, per the manufacturer specification sheet.

What voltages is the Tradewinds Power TP150TP available in?

The Tradewinds Power TP150TP is offered in 120/240 V, 120/208 V, 480/277 V, 3-phase.

What battery does the Tradewinds Power TP150TP use?

The Tradewinds Power TP150TP uses Not specified batteryies, 12 V each, group Not specified, per the manufacturer specification sheet.

Which alternator is fitted to the Tradewinds Power TP150TP?

The Tradewinds Power TP150TP uses a Marathon 4-pole, 12-wire brushless generator, single bearing alternator.

What air filter fits the Tradewinds Power TP150TP?

The Tradewinds Power TP150TP uses air filter part numbers Donaldson P635904, Donaldson P635980.

Fuel consumption

RatingLoadL/hgal/h
25%25%3.2512.2
50%50%5.8622.2
75%75%8.4832.1
Prime10.4939.7
Standby11.3943.1

Available documents

Reference — TP150TP (Tradewinds Power)

This page was generated from the 1 manufacturer document above by automated extraction; every figure shown is copied from one of them. How the data is compiled.