HomeSDMOSDMO XS 650 UC

SDMO XS 650 UC Generator Set

The SDMO XS 650 UC is a 650 kW (813 kVA) Diesel standby generator set powered by a MTU 12V 2000 G43 engine. It is available at 480 V, 277 V, 440 V, 254 V, 380 V, 220 V, 240 V, 120 V, 127 V and 208 V, 3-phase, 60 Hz and rated 12 A. It holds about 5.1 L (1.3 gal) of oil and 5.9 L (1.6 gal) of coolant, with a maximum ambient rating of 1457 °C. Starting uses 1 group-12 battery at 12 V. The set measures 3981×1630×1950 mm (156.7×64.2×76.8 in), weighs about 5216 kg (11499 lb) and produces 78 dBA at 23 m. An integrated tank holds 1000 L (264.2 gal), roughly 12 hours of runtime.

650 kW
Standby
23.88 L
Displacement
5.1 L
Oil capacity
2
Document types

Compare with other 650–655 kW Diesel generators →

Specifications

FuelDiesel
Frequency60.0 Hz
Standby power650 kW
Standby kVA813
Prime power591 kW
EmissionsTiers I
ControllerLS
Oil capacity5.1 L
AlternatorLeroy-Somer LSA491M5
Voltage options480 V, 277 V, 440 V, 254 V, 380 V, 220 V, 240 V, 120 V, 127 V, 208 V
Phase3
Rated current12 A
Power factor0.8
Circuit breaker5.9 A
Battery group12V2000G42
Battery voltage12 V
Battery quantity1
Coolant capacity5.9 L
Max ambient1457 °C
Dimensions (L×W×H)3981×1630×1950 mm
Dry weight5216 kg
Sound level78.0 dBA @ 23 m
Fuel tank1000.0 L
Tank runtime12 hr

Engine

MTU 12V 2000 G43
Oil capacity67.0 L
Coolant capacity90.0 L
Displacement23.88 L
Aspirationturbocharged and charge air cooled
Rated speed1800 rpm

Maintenance & consumables

for the MTU 12V 2000 G43
ItemSpecCapacityPart #Interval
Air filterStandard air-filter1000 hr find
Fuel filterFuel cooling radiator1000 hr find
Oil filterLub oil drain pump1000 hr find
BeltStainless steel bellows1000 hr find
CoolantCoolant heater 220/240 V1000.0 L1000 hr
OilOil centrifuge filter1000.0 L1000 hr

Common questions

What is the power rating of the SDMO XS 650 UC?

The SDMO XS 650 UC is rated 650 kW standby (813.0 kVA).

What engine does the SDMO XS 650 UC use?

The SDMO XS 650 UC is powered by the MTU 12V 2000 G43 engine.

What fuel does the SDMO XS 650 UC use?

The SDMO XS 650 UC runs on Diesel.

What is the oil capacity of the SDMO XS 650 UC?

The MTU 12V 2000 G43 engine in the SDMO XS 650 UC has an oil capacity of 67.0 liters.

What alternator does the SDMO XS 650 UC use?

The SDMO XS 650 UC uses a Leroy-Somer LSA491M5 alternator.

Fuel consumption

RatingLoadL/hgal/h
Prime90.523.9
Prime75%130.534.5
Prime100%174.046.0
Standby100%1000.01000.0
Standby110%1860.0491.4

Available documents

Spec sheet — XS650UC (SDMO)Parts manual — Power Products 60 Hz en2 (SDMO)