HomeSDMOSDMO TM30UC

SDMO TM30UC Generator Set

The SDMO TM30UC is a 30 kW (38 kVA) Diesel standby generator set powered by a Mitsubishi S4S.Y262SD engine. It is available at 480/277 V, 440/254 V, 240/120 V, 230/115 V, 220/127 V and 208/120 V, 3-phase, 60 Hz and rated 105 A. It holds about 10 L (2.6 gal) of oil and 8.9 L (2.4 gal) of coolant, with a maximum ambient rating of 50 °C. Starting uses 1 group-12 battery at 12 V. The set measures 1515×780×1120 mm (59.6×30.7×44.1 in), weighs about 600 kg (1323 lb) and produces 80.1 dBA at 1 m. An integrated tank holds 36 L (9.5 gal), roughly N/A hours of runtime.

30 kW
Standby
3.33 L
Displacement
10.0 L
Oil capacity
1
Document types

How to read your SDMO serial & model number →

Typical fuel consumption for 30–35 kW Diesel generators →

Compare with other 30–35 kW Diesel generators →

Specifications

FuelDiesel
Frequency60.0 Hz
Standby power30 kW
Standby kVA38
Prime power27 kW
EmissionsN/A
ControllerNexys, Telys
Oil capacity10.0 L
AlternatorMecc Alte ECO28VL (4-pole, Class H insulation)
Voltage options480/277 V, 440/254 V, 240/120 V, 230/115 V, 220/127 V, 208/120 V
Phase3
Rated current105 A
Power factor0.8
Circuit breaker105 A
Battery group12 V
Battery voltage12 V
Battery quantity1
Coolant capacity8.9 L
Max ambient50 °C
Dimensions (L×W×H)1515×780×1120 mm
Dry weight600 kg
Sound level80.1 dBA @ 1 m
Fuel tank36.0 L
Tank runtimeN/A hr

Engine

Mitsubishi S4S.Y262SD
Oil capacity9.0 L
Coolant capacity8.9 L
Displacement3.33 L
AspirationN/A
Rated speed1800 rpm

Common questions

What is the power rating of the SDMO TM30UC?

The SDMO TM30UC is rated 30 kW standby (38.0 kVA).

Which engine powers the SDMO TM30UC?

The SDMO TM30UC is powered by the Mitsubishi S4S.Y262SD engine.

What fuel does the SDMO TM30UC use?

The SDMO TM30UC runs on Diesel.

What is the oil capacity of the SDMO TM30UC?

The Mitsubishi S4S.Y262SD engine in the SDMO TM30UC has an oil capacity of 9.0 liters.

What alternator does the SDMO TM30UC use?

The SDMO TM30UC uses a Mecc Alte ECO28VL alternator. It has 4 poles. Insulation class H.

Fuel consumption

RatingLoadL/hgal/h
Prime6.01.6
Prime50%6.01.6
Prime75%8.22.2
Prime100%9.82.6
Standby75%8.22.2
Standby100%11.53.0

Available documents

Spec sheet — T30UC (SDMO)Spec sheet — T30UCM (SDMO)Spec sheet — TM30UC (SDMO)Spec sheet — TM30UCM (SDMO)