Home›SDMO›SDMO G150

SDMO G150 Generator Set

The SDMO G150 is a 100 kW (100 kVA) Natural Gas standby generator set powered by a Detroit Diesel S50G engine. It is available at 120/208 V, 120/240 V, 127/220 V, 139/240 V, 220/380 V, 277/480 V and 347/600 V, 3-phase, 60 Hz and rated 520 A. It holds about 21 L (5.5 gal) of oil and 16.1 L (4.3 gal) of coolant, with a maximum ambient rating of 50 °C. Starting uses 2 group-2 batteries rated 625 CCA at 12 V.

100 kW
Standby
21.0 L
Oil capacity
1
Document types

How to read your SDMO serial & model number →

Typical fuel consumption for 100–105 kW Natural Gas generators →

Compare with other 100–105 kW Natural Gas generators →

Specifications

FuelNatural Gas
Frequency60.0 Hz
Standby power100 kW
Standby kVA100
Prime power91 kW
Controllermicroprocessor controller
Oil capacity21.0 L
AlternatorSDMO
Voltage options120/208 V, 120/240 V, 127/220 V, 139/240 V, 220/380 V, 277/480 V, 347/600 V
Phase3
Rated current520 A
Power factor0.8
Circuit breaker520 A
Battery group2
Battery cranking625 CCA
Battery voltage12 V
Battery quantity2
Coolant capacity16.1 L
Max ambient50 °C

Engine

Detroit Diesel S50G
Oil capacity21.0 L
Coolant capacity16.1 L
AspirationTurbocharged
Rated speed1800 rpm

Common questions

What is the power rating of the SDMO G150?

The SDMO G150 is rated 100 kW standby (100.0 kVA).

What engine is in the SDMO G150?

The SDMO G150 is powered by the Detroit Diesel S50G engine.

What kind of fuel does the SDMO G150 run on?

The SDMO G150 runs on Natural Gas.

What's the oil capacity on a SDMO G150?

The Detroit Diesel S50G engine in the SDMO G150 has an oil capacity of 21.0 liters.

What is the cooling system capacity of the SDMO G150?

The SDMO G150 cooling system holds 16.1 liters (4.3 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

What is the prime power rating of the SDMO G150?

The SDMO G150 is rated 91 kW prime (91 kVA), against 100 kW standby.

What voltages is the SDMO G150 available in?

The SDMO G150 is offered in 120/208 V, 120/240 V, 127/220 V, 139/240 V, 220/380 V, 277/480 V, 3-phase.

How many cold cranking amps does the SDMO G150 require?

The SDMO G150 uses 2 batteryies, 12 V each, 625 CCA, group 2, per the manufacturer specification sheet.

Which alternator is fitted to the SDMO G150?

The SDMO G150 uses a SDMO alternator.

Fuel consumption

RatingLoadL/hgal/h
Prime100%54.014.27
Standby50%31.08.19
Standby75%42.011.1
Standby100%54.014.27

Available documents

Spec sheet — G150U (SDMO)

This page was generated from the 1 manufacturer document above by automated extraction; every figure shown is copied from one of them. How the data is compiled.