Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 1250 kW |
| Standby kVA | 1250 |
| Prime power | 1137 kW |
| Emissions | Tier I |
| Controller | Electronic Governor |
| Oil capacity | 11.5 L |
| Alternator | 501 M7 |
| Voltage options | 480/277 V, 440/254 V, 220/127 V, 208/120 V |
| Phase | Three phase |
| Rated current | 153 A |
| Power factor | Not specified |
| Circuit breaker | 153 A |
| Battery group | Not specified |
| Battery voltage | Not specified V |
| Battery quantity | Not specified |
| Max ambient | Not specified °C |
| Tank runtime | Not specified hr |
Filters for the MTU 12V4000G41
1Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.
Listed for this engine in only one kind of machine, so they may depend on how the engine was installed:
| System | Filter | Description | Cross-references | |
|---|---|---|---|---|
| Fuel / water separator | P550849 | Fuel Filter, Water Separator Cartridge | NAPA 3763, BALDWIN PF7928, DAVCO 102526, DAVCO 102527 | FridayParts $20.90 KuduParts $39.00 |
Common questions
How many kW is the SDMO EXEL 2 X 1250 UC?
The SDMO EXEL 2 X 1250 UC is rated 1250 kW standby (1250.0 kVA).
What engine does the SDMO EXEL 2 X 1250 UC use?
The SDMO EXEL 2 X 1250 UC is powered by the MTU 12V4000G41 engine.
What kind of fuel does the SDMO EXEL 2 X 1250 UC run on?
The SDMO EXEL 2 X 1250 UC runs on Diesel.
What is the oil capacity of the SDMO EXEL 2 X 1250 UC?
The MTU 12V4000G41 engine in the SDMO EXEL 2 X 1250 UC has an oil capacity of 11.5 liters.
What is the prime power rating of the SDMO EXEL 2 X 1250 UC?
The SDMO EXEL 2 X 1250 UC is rated 1137 kW prime (1137 kVA), against 1250 kW standby.
What voltages is the SDMO EXEL 2 X 1250 UC available in?
The SDMO EXEL 2 X 1250 UC is offered in 480/277 V, 440/254 V, 220/127 V, 208/120 V, Three phase-phase.
How many cold cranking amps does the SDMO EXEL 2 X 1250 UC require?
The SDMO EXEL 2 X 1250 UC uses Not specified batteryies, Not specified V each, group Not specified, per the manufacturer specification sheet.
What alternator comes on the SDMO EXEL 2 X 1250 UC?
The SDMO EXEL 2 X 1250 UC uses a 501 M7 alternator.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Standby | 75% | 34.5 | 12.2 |
Available documents
This page was generated from the 1 manufacturer document above by automated extraction; every figure shown is copied from one of them. How the data is compiled.