Service parts for the WPSP-200S
Grouped by system, with how many of each the parts manual calls for.
Fuel system
1 requiredOil system
1 requiredPrices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.
Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 50.0 Hz |
| Standby power | 160 kW |
| Prime power | 144 kW |
| Emissions | StageⅡ & Tier 4 |
| Controller | DSE 6000 |
| Oil capacity | 18.0 L |
| Alternator | Stamford/AvK UC Alternator |
| Voltage options | 380 V, 415 V |
| Phase | 3 Phase |
| Coolant capacity | 21 L |
| Max ambient | 50 °C |
| Dimensions (L×W×H) | 3380×1630×1950 mm |
| Dry weight | 2800 kg |
| Fuel tank | 350.0 L |
Engine
| Oil capacity | 16.5 L |
|---|---|
| Coolant capacity | 21.0 L |
| Displacement | 7.0 L |
| Aspiration | Turbo |
| Rated speed | 1500 rpm |
Filters for the Perkins 1106A-70TAG3
5Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.
| System | Filter | Description | Cross-references | |
|---|---|---|---|---|
| Oil filter | P550920 | Lube Filter, Spin-On Full Flow | PERKINS 2654A111, PERKINS 4627133, NAPA 7325, BALDWIN B7378 | KuduParts $45.00 FridayParts $46.80 |
Listed for this engine in only one kind of machine, so they may depend on how the engine was installed:
| System | Filter | Description | Cross-references | |
|---|---|---|---|---|
| Fuel filter | P502420 | Fuel Filter, Cartridge | PERKINS 2656F823, PERKINS 4415122, NAPA 600488, CLAAS 0011377510 | buy |
| Fuel filter | P550974 | Fuel Filter, In-Line | PERKINS 102601, NAPA 3270, BLAW KNOX 0016481600, VERMEER 102995001 | FridayParts $356.80 |
| Fuel / water separator | P551425 | Fuel Filter, Water Separator Cartridge | PERKINS 26560139, PERKINS 26560141, NAPA 3586, BALDWIN BF7677-D | FridayParts $20.00 |
| Fuel / water separator | P551426 | Fuel Filter, Water Separator Cartridge | PERKINS 26560920, BALDWIN BF9830-D, SULLAIR 1006374, JCB 320A7128 | KuduParts $34.00 |
Same engine, other brands
5 brandsThe Perkins 1106A-70TAG3 in this set also powers 7 generator sets sold under 5 other brands. Service parts and maintenance intervals for the engine are shared; enclosure, alternator, controller and ratings are not.
| Brand | Models |
|---|---|
| FG Wilson | MJB 250 MB4, Mark V, P200 |
| AKSA | AD220 |
| Caps | CP200-TP1 |
| Lees | LSP200S3 |
| MTU | 1106A-70TAG3 |
Maintenance & consumables
for the Perkins 1106A-70TAG3| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | — | ||||
| Fuel filter | 2656F823 | Amazon eBay $140.00 KuduParts $71.00 | |||
| Oil filter | 2654A111 | Amazon eBay $23.99 NAPA $22.21 FridayParts $28.06 KuduParts $48.00 | |||
| Battery | Maintenance-free and anti-explosion battery | — | |||
| Belt | — | ||||
| Coolant | — | ||||
| Coolant filter | — | ||||
| Oil | 18.0 L | — | 500 hr | ||
| Spark plug | — |
Common questions
How many kW is the Perkins WPSP-200S?
The Perkins WPSP-200S is rated 160 kW standby.
What engine is in the Perkins WPSP-200S?
The Perkins WPSP-200S is powered by the Perkins 1106A-70TAG3 engine.
Is the Perkins WPSP-200S diesel or gas?
The Perkins WPSP-200S runs on Diesel.
What's the oil capacity on a Perkins WPSP-200S?
The Perkins 1106A-70TAG3 engine in the Perkins WPSP-200S has an oil capacity of 16.5 liters.
What is the coolant capacity of the Perkins WPSP-200S?
The Perkins WPSP-200S cooling system holds 21 liters (5.5 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the continuous rating of the Perkins WPSP-200S?
The Perkins WPSP-200S is rated 144 kW prime (176 kVA), against 160 kW standby.
What is the dry weight of the Perkins WPSP-200S?
The Perkins WPSP-200S has a dry weight of 2800 kg (6172 lb).
What size fuel tank does the Perkins WPSP-200S have?
The Perkins WPSP-200S has a 350 liter (92 US gallon) fuel tank.
What voltage does the Perkins WPSP-200S produce?
The Perkins WPSP-200S is offered in 380 V, 415 V, 3 Phase-phase.
What alternator comes on the Perkins WPSP-200S?
The Perkins WPSP-200S uses a Stamford/AvK UC Alternator alternator.
Which oil filter part number does the Perkins WPSP-200S take?
The Perkins WPSP-200S uses oil filter part number 2654A111.
What fuel filter does the Perkins WPSP-200S use?
The Perkins WPSP-200S uses fuel filter part number 2656F823.
Troubleshooting
27Fault codes
| Code | Meaning | Cause | Remedy |
|---|---|---|---|
| ECU Amber | ECU Amber | This indicates a fault condition detected by the engine ECU and transmitted to the DSE controller. | |
| ECU Red | ECU Red | This indicates a fault condition detected by the engine ECU and transmitted to the DSE controller. | |
| ECU Data Fail | ECU Data Fail | Indicates failure of the CAN data link to the engine ECU. | Check all wiring and termination resistors (if required). |
| SPN=131166, FMI=8, OC=127 | Water Level Low | ||
| ECU Warning | ECU Warning — Warning | If the module is configured for CAN and receives an “error” message from the ECU, ‘ECU Warning” is shown on the module’s display as a warning alarm. | |
| Water Level Low | SPN=131166 , FMI=8, OC=127 |
Symptoms & remedies
| Symptom | Cause | Remedy |
|---|---|---|
| Unit is inoperative / Read/Write configuration does not operate | Check the battery and wiring to the unit. Check the DC supply. Check the DC fuse. | |
| Unit shuts down | Check DC supply voltage is not above 35 Volts or below 9 Volts; Check the operating temperature is not above 70°C. Check the DC fuse. | |
| Fail to Start is activated after pre-set number of attempts to start | Check wiring of fuel solenoid. Check fuel. Check battery supply. Check battery supply is present on the Fuel output of the module. Check the speed-sensing signal is present on the module’s inputs. Refer to engine manual. | |
| Continuous starting of generator when in the Auto Mode | Check that there is no signal present on the “Remote Start” input. Check configured polarity is correct. | |
| Generator fails to start on receipt of Remote Start signal. | Check Start Delay timer has timed out.; Check signal is on “Remote Start” input. Confirm correct configuration of input is configured to be used as “Remote Start”. | |
| Generator fails to start on receipt of Remote Start signal. | The oil pressure switch or sensor is indicating low oil pressure to the controller; Depending upon configuration, the set does not start if oil pressure is not low. | Check that the oil pressure switch or sensor is indicating low oil pressure to the controller. |
| Pre-heat inoperative | Check wiring to engine heater plugs. Check battery supply. Check battery supply is present on the Pre-heat output of module. Check pre-heat configuration is correct. | |
| Starter motor inoperative | Check wiring to starter solenoid. Check battery supply. Check battery supply is present on the Starter output of module. Ensure oil pressure switch or sensor is indicating the “low oil pressure” state to the controller. | |
| Engine runs but generator does not take load | Check Warm up timer has timed out.; Ensure generator load inhibit signal is not present on the module inputs.; Check connections to the switching device.; Note that the set does not take load in Manual Mode unless there is an active load signal. | |
| Incorrect reading on Engine gauges | Check engine is operating correctly. | |
| Fail to stop alarm when engine is at rest | Check that sensor is compatible with the module and that the module configuration is suited to the sensor. | |
| Oil pressure low fault operates after engine has fired | Check engine oil pressure. Check oil pressure switch/sensor and wiring. Check configured polarity (if applicable) is correct (i.e. Normally Open or Normally Closed) or that sensor is compatible with the module and is correctly configured. | |
| Coolant temp high fault operates after engine has fired. | Check engine temperature. Check switch/sensor and wiring. Check configured polarity (if applicable) is correct (i.e. Normally Open or Normally Closed) or that sensor is compatible with the module. | |
| Shutdown fault operates | Check relevant switch and wiring of fault indicated on LCD display. Check configuration of input. | |
| Electrical Trip fault operates | Check relevant switch and wiring of fault indicated on LCD display. Check configuration of input. | |
| Warning fault operates | Check relevant switch and wiring of fault indicated on LCD display. Check configuration of input. | |
| Inaccurate generator measurements on controller display | Check that the CT primary, CT secondary and VT ratio settings are correct for the application.; Check that the CTs are wired correctly with regards to the direction of current flow (p1,p2 and s1,s2) and additionally ensure that CTs are connected to the correct phase (errors occur if CT1 is connected to phase 2).; Remember to consider the power factor (kW = kVA x powerfactor).; The controller is true RMS measuring so gives more accurate display when compared with an ‘averaging’ meter such as an analogue panel meter or some lower specified digital multimeters.; Accuracy of the controller is better than 1% of full scale. Generator voltage full scale is 415 V ph-N, accuracy is ±4.15 V (1 % of 415 V ). | |
| DSE2130 ID 0 to 3 Analogue Input E to H High | The module detected that an analogue input value of a DSE2130 had risen above the Flexible Sensor High Pre-Alarm Trip level. | |
| DSE2130 ID 0 to 3 Analogue Input E to H Low | The module detected that an analogue input value of a DSE2130 had fallen below the Flexible Sensor Low Pre-Alarm Trip level. | |
| DSE2130 ID 0 to 3 Digital Input A to H | The module detected that a digital input configured to create a fault condition on a DSE2130 expansion module became active and the appropriate LCD message displayed. | |
| DSE2131 ID 0 to 3 Analogue Input A to J Low | The module detected that an analogue input value of a DSE2131 had fallen below the Flexible Sensor Low Pre-Alarm Trip level. |
Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.
Parts
1| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 057-289 | ISSUE: 2 | Service part / kit | Amazon eBay |
Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Available documents
This page was generated from the 1 manufacturer document above by automated extraction; every figure shown is copied from one of them. How the data is compiled.