HomePerkinsPerkins 2506A-E15TAG3

Perkins 2506A-E15TAG3 Generator Set

The Perkins 2506A-E15TAG3 is a 450 kW (563 kVA) diesel standby generator set. It operates at 60 Hz.

450 kW
Standby
3
Document types

How to read your Perkins serial & model number →

Typical fuel consumption for 450–455 kW Diesel generators →

Compare with other 450–455 kW Diesel generators →

Specifications

Fueldiesel
Frequency60.0 Hz
Standby power450 kW
Standby kVA563
Prime power410 kW
Power factor0.8

Filters & service parts

model family
ItemSpecCapacityPart #Interval
Air filterpaper element 18 inch diameter
Fuel filterfiltration level 2 µm
Oil filter
Battery2x 12V 128 Ah
Coolant50% inhibited ethylene glycol or 50% inhibited propylene glycol and 50% clean fresh water; where there is no likelihood of ambient temperatures below 10 °C, clean 'soft' water may be used, treated with 1% by volume of Perkins inhibitor58.0 litres
Oil0W3062.0 litres

Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.

Service specifications

39
TypeItemValueUnitCondition
ClearanceMaximum static pressure head (fuel)4m
ClearanceMaximum suction head at fuel lift pump inlet3m
ClearanceOil filter screen spacing30µm
OtherCentre of gravity (bare dry engine) above crankshaft centre line240mm
OtherCentre of gravity (bare dry engine) forward of rear face of cylinder block570mm
OtherMaximum static bending moment at rear face of block1356Nm
OtherSound pressure level, bare engine (without inlet and exhaust) at 1 metre103dB(A)1500 rev/min
OtherSound pressure level, bare engine (without inlet and exhaust) at 1 metre105dB(A)1800 rev/min
OtherSteady state stability at constant speed+/- 0,25%constant speed
PressureFuel lift pump pressure550kPa
PressureInjector pressure200MPa
PressureLubricating oil pressure at rated speed420kPaat rated speed
PressureLubricating oil pressure nominal (minimum)200kPa
PressureMaximum air intake restriction - clean filter3.7kPa
PressureMaximum air intake restriction - dirty filter6.2kPa
PressureMaximum exhaust back pressure6.8kPa
PressureMaximum permissible restriction to coolant pump flow30kPa(626.6 lbf/in²)
PressureMaximum pressure in crankcase water jacket276kPa
PressureMaximum static pressure on coolant pump170kPa
PressureOil relief valve opens (pressure difference)255 +/- 20kPa
PressureRadiator pressure cap setting (minimum)69kPa
SpeedCoolant pump speed @ 1500 rev/min1622rev/minengine at 1500 rev/min
SpeedCoolant pump speed @ 1800 rev/min1946rev/minengine at 1800 rev/min
SpeedMinimum cranking speed100rev/min
SpeedMinimum mean cranking speed (cold start, 5 to -25 °C)120rev/mincold start
TemperatureCoolant exit temperature, 1500 and 1800 rev/min88 to 107°C1500 rev/min and 1800 rev/min
TemperatureCooling water maximum exit temperature< 107°C
TemperatureFuel inlet temperature (to be less than)55°C
TemperatureOil temperature (in rail) maximum continuous operation114°C
TemperatureTemperature rise across engine with inhibited coolant - prime power9°Cprime power @ 1500 and 1800 rev/min
TemperatureTemperature rise across engine with inhibited coolant - standby power10°Cstandby power @ 1500 and 1800 rev/min
TemperatureThermostat operation range88 to 98°C
TorqueBattery (positive) connection24Nm1/2" x 13 TPI
TorqueBattery (positive) terminal11.3NmM6 x 1, nominal
TorqueGround (negative) connection24Nm1/2" x 13 TPI
TorqueGround (negative) terminal6Nm1/4" UNC x 20 TPI
TorqueIndicator light terminal2.25NmM4 x 0.7, nominal
TorqueRelay terminal2.25NmM4 x 0.7, nominal
TorqueSolenoid (positive) connection2.5NmNo 10 x 32 TPI

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Coolant50% inhibited ethylene glycol or 50% inhibited propylene glycol and 50% clean fresh water58.0 litresWhere there is no likelihood of ambient temperatures below 10 °C, clean 'soft' water may be used, treated with 1% by volume of Perkins inhibitor in the cooling system. Maximum top tank temperature 107 °C.
Engine oil15W40API CI4 or ACEA E562.0 litresMultigrade oil 15W40 recommended; total system capacity 62,0 litres, maximum sump capacity 53,0 litres, minimum sump capacity 45,0 litres. Viscosity chart W1355 gives 0W, 5W20, 10W30, 15W40, 20W50 against ambient temperature -30 to 50 °C. Cold start: 15W40 for 5 to -10 °C, 0W30 for -11 to -25 °C.
FuelBS 2869: Part 2 1998 Class A2 or ASTM D975 D2
FuelBS2869 1998 Class A2BS2869 class A2Density 0·820 (kgm³ @ 15 °C). Fuel inlet temperature to be less than 55 °C.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What size generator is the Perkins 2506A-E15TAG3?

The Perkins 2506A-E15TAG3 is rated 450 kW standby (563.0 kVA).

Is the Perkins 2506A-E15TAG3 diesel or gas?

The Perkins 2506A-E15TAG3 runs on diesel.

Available documents

Engine spec — 2506A-E15TAG3 ElectropaK PN1843 (Perkins)Engine spec — 2506A-E15TAG3 ElectropaK (pn1843-Sept06) (Perkins)Engine spec — 2506A-E15TAG3(TPD1581e2) (Perkins)Engine spec — Perkins Engines Guide www.engine.od.ua (Perkins)Spec sheet — GenSet Power Selector Unregulated PN3012 (Perkins)Reference — GenSet Selector Unregulated Iss2 PN1542 Jan10 (Perkins)