Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 50.0 Hz |
| Standby power | 240 kW |
| Standby kVA | 300 |
| Prime power | 239 kW |
| Controller | PowerWizard 1.1+ |
| Oil capacity | 59.5 L |
| Alternator | Ll5014L LL5014L |
| Voltage options | 240 V, 380 V |
| Phase | 3 Phase |
| Power factor | 0.8 |
| Circuit breaker | 1500 A |
| Coolant capacity | 64.8 L |
| Max ambient | 50 °C |
| Dimensions (L×W×H) | 3300×1100×1848 mm |
| Dry weight | 2724 kg |
| Wet weight | 2755 kg |
| Fuel tank | 60.0 L |
Engine
| Oil capacity | 36.0 L |
|---|---|
| Coolant capacity | 30.9 L |
| Displacement | 9.3 L |
| Aspiration | Turbocharged aftercooled |
| Rated speed | 1500 rpm |
Same engine, other brands
2 brandsThe Perkins 1606A-E93TAG5 in this set also powers 2 generator sets sold under 2 other brands. Service parts and maintenance intervals for the engine are shared; enclosure, alternator, controller and ratings are not.
| Brand | Models |
|---|---|
| FG Wilson | P330H-1 |
| Olympian | GEH330-1 |
Maintenance & consumables
for the Perkins 1606A-E93TAG5| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Oil | — | 500 hr |
Common questions
What is the power rating of the Perkins 1606A-E93TAG5?
The Perkins 1606A-E93TAG5 is rated 240 kW standby (300.0 kVA).
What engine is in the Perkins 1606A-E93TAG5?
The Perkins 1606A-E93TAG5 is powered by the Perkins 1606A-E93TAG5 engine.
What fuel does the Perkins 1606A-E93TAG5 use?
The Perkins 1606A-E93TAG5 runs on Diesel.
What's the oil capacity on a Perkins 1606A-E93TAG5?
The Perkins 1606A-E93TAG5 engine in the Perkins 1606A-E93TAG5 has an oil capacity of 36.0 liters.
What is the cooling system capacity of the Perkins 1606A-E93TAG5?
The Perkins 1606A-E93TAG5 cooling system holds 64.8 liters (17.1 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the continuous rating of the Perkins 1606A-E93TAG5?
The Perkins 1606A-E93TAG5 is rated 239 kW prime (330 kVA), against 240 kW standby.
How much does the Perkins 1606A-E93TAG5 weigh?
The Perkins 1606A-E93TAG5 has a dry weight of 2724 kg (6005 lb).
How big is the fuel tank on the Perkins 1606A-E93TAG5?
The Perkins 1606A-E93TAG5 has a 60 liter (16 US gallon) fuel tank.
What voltage does the Perkins 1606A-E93TAG5 produce?
The Perkins 1606A-E93TAG5 is offered in 240 V, 380 V, 3 Phase-phase.
What alternator does the Perkins 1606A-E93TAG5 use?
The Perkins 1606A-E93TAG5 uses a Ll5014L LL5014L alternator.