Specifications
| Fuel | diesel |
|---|---|
| Frequency | 50.0 Hz |
| Standby power | 220 kW |
| Standby kVA | 275 |
| Prime power | 200 kW |
| Emissions | Stage 2 |
| Controller | PowerWizard 1.1+ |
| Oil capacity | 26.4 L |
| Alternator | Ll5014J P250H2 / P275HE2/4PP/0211/PT |
| Voltage options | 380 V, 415 V, 50 V, 220/110 V, 230/115 V, 400/230 V |
| Power factor | 0.8 |
| Circuit breaker | 1500 A |
| Coolant capacity | 67.3 L |
| Max ambient | 50 °C |
| Dimensions (L×W×H) | 1822×875×1369 mm |
| Dry weight | 895 kg |
| Wet weight | 2252 kg |
| Fuel tank | 60.3 L |
Engine
| Oil capacity | 26.4 L |
|---|---|
| Coolant capacity | 37.2 L |
| Displacement | 8.7 L |
| Aspiration | Turbocharged, air-to-air chargecooled |
| Rated speed | 1500 rpm |
Maintenance & consumables
for the Perkins 1306C-E87TAG6| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | — | ||||
| Fuel filter | — | ||||
| Oil filter | — | 450 hr | |||
| Battery | — | ||||
| Belt | — | ||||
| Coolant | 37.2 litres | — | |||
| Oil | 15W40 to ACEA E3 or API CG4 | 67.3 litres | — | 450 hr | |
| Spark plug | — |
Service intervals
2| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| oil and filter | Change | 450 hr | 1300 Series EDi - oil and filter changes at 450 hours reduce down time | |
| service interval | Other | 500 hr | 1100C range - 500 hour service intervals |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Recommended fluids
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Engine oil | API CH4/ACEA E5 | 1100 Series (1103C/1104C) | |||
| Engine oil | 15W40 | ACEA E3 or API CG4 | 1300 Series EDi | ||
| Engine oil | multi-grade oil | API-CH4/CI4 | 1106D-E66TAG | ||
| Engine oil | single or multigrade oil | ACEA E1 E2 or CD/SD | 1000 Series | ||
| Fuel | BS 2869 Part 2 1998 Class A2 or ASTM D975 D2 | 1000/1300 Series |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Common questions
What is the power rating of the Perkins 1306C-E87TAG6?
The Perkins 1306C-E87TAG6 is rated 220 kW standby (275.0 kVA).
What engine does the Perkins 1306C-E87TAG6 use?
The Perkins 1306C-E87TAG6 is powered by the Perkins 1306C-E87TAG6 engine.
What kind of fuel does the Perkins 1306C-E87TAG6 run on?
The Perkins 1306C-E87TAG6 runs on diesel.
What is the oil capacity of the Perkins 1306C-E87TAG6?
The Perkins 1306C-E87TAG6 engine in the Perkins 1306C-E87TAG6 has an oil capacity of 26.4 liters.
What alternator does the Perkins 1306C-E87TAG6 use?
The Perkins 1306C-E87TAG6 uses a Ll5014J P250H2 / P275HE2/4PP/0211/PT alternator.