Service parts for the 1006TAG2
Grouped by system, with how many of each the parts manual calls for.
Oil system
1 requiredPrices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.
Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 50.0 Hz |
| Standby power | 132 kW |
| Standby kVA | 165 |
| Prime power | 120 kW |
| Emissions | Non-compliant |
| Controller | Electronic |
| Oil capacity | 19.0 L |
| Alternator | Leroy-Somer LSA 44.2 M95 (4-pole, Class H insulation) |
| Voltage options | 400 V, 480 V |
| Phase | 1 |
| Rated current | 120.0 A |
| Power factor | 0.8 |
| Circuit breaker | 120.0 A |
| Battery group | 12 |
| Battery voltage | 12 V |
| Battery quantity | 1 |
| Coolant capacity | 41.0 L |
| Max ambient | 53 °C |
| Dimensions (L×W×H) | 1685×773×1065 mm |
| Dry weight | 586 kg |
| Tank runtime | N/A hr |
Engine
| Oil capacity | 19.0 L |
|---|---|
| Coolant capacity | 41.0 L |
| Displacement | 5.99 L |
| Aspiration | Turbocharged, air-to-air aftercooled |
| Rated speed | 1500 rpm |
Maintenance & consumables
for the Perkins 1006TAG2| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | Replaceable Element | — | |||
| Fuel filter | Replaceable Element | — | |||
| Oil filter | Twin spin-on full flow | T74105021 | Amazon $32.99 eBay $19.00 | ||
| Battery | 12 volt starter motor and 55 amp alternator | — | |||
| Belt | Spin-On, Full Flow | — | |||
| Coolant | Thermostat controlled cooling system | — | |||
| Oil | — | ||||
| Spark plug | Replaceable Element | — |
Service intervals
2| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| oil and filter | Change | 450 hr | 1300 Series EDi - oil and filter changes at 450 hours reduce down time | |
| service interval | Other | 500 hr | 1100C range - 500 hour service intervals |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Recommended fluids
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Engine oil | API CH4/ACEA E5 | 1100 Series (1103C/1104C) | |||
| Engine oil | 15W40 | ACEA E3 or API CG4 | 1300 Series EDi | ||
| Engine oil | multi-grade oil | API-CH4/CI4 | 1106D-E66TAG | ||
| Engine oil | single or multigrade oil | ACEA E1 E2 or CD/SD | 1000 Series | ||
| Fuel | BS 2869 Part 2 1998 Class A2 or ASTM D975 D2 | 1000/1300 Series |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Common questions
What size generator is the Perkins 1006TAG2?
The Perkins 1006TAG2 is rated 132 kW standby (165.0 kVA).
What engine is in the Perkins 1006TAG2?
The Perkins 1006TAG2 is powered by the Perkins 1006TAG2 engine.
What kind of fuel does the Perkins 1006TAG2 run on?
The Perkins 1006TAG2 runs on Diesel.
What is the oil capacity of the Perkins 1006TAG2?
The Perkins 1006TAG2 engine in the Perkins 1006TAG2 has an oil capacity of 19.0 liters.
What alternator does the Perkins 1006TAG2 use?
The Perkins 1006TAG2 uses a Leroy-Somer LSA 44.2 M95 alternator. It has 4 poles. Insulation class H.
Which oil filter part number does the Perkins 1006TAG2 take?
The Perkins 1006TAG2 uses oil filter part number T74105021.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 100% | 41.0 | 9.0 |
| Prime | 110% | 45.0 | 9.9 |
| Standby | 50% | 20.0 | 4.4 |
| Standby | 75% | 31.0 | 6.8 |