Home›Olympian›Olympian G50F3

Olympian G50F3 Generator Set

The Olympian G50F3 is a 50 kW (62.5 kVA) LP standby generator set powered by a Ford ESG642 engine. It is available at 277/480 V, 120/240 V and 120/208 V, 3-phase and 60 Hz. It holds about 5.7 L (1.5 gal) of oil and 20 L (5.3 gal) of coolant. The set measures 2200×1000×1206 mm (86.6×39.4×47.5 in).

50 kW
Standby
4.2 L
Displacement
5.7 L
Oil capacity
0
Document types

How to read your Olympian serial & model number →

Typical fuel consumption for 50–55 kW Bi-Fuel (NG/LP) generators →

Compare with other 50–55 kW Bi-Fuel (NG/LP) generators →

Specifications

FuelLP
Frequency60.0 Hz
Standby power50 kW
Standby kVA62
Prime power42.5 kW
Controller2001
Oil capacity5.7 L
AlternatorSR4B (4-pole)
Voltage options277/480 V, 120/240 V, 120/208 V
Phase3
Power factor0.8
Dimensions (L×W×H)2200×1000×1206 mm
Wet weight770 kg

Engine

Ford ESG642
Oil capacity5.7 L
Coolant capacity20.0 L
Displacement4.2 L
AspirationNatural
Rated speed1800 rpm

Maintenance & consumables

for the Ford ESG642
ItemSpecCapacityPart #Interval
Air filterDry, light duty—
Oil filterSpin-On, Full Flow—
Coolant20.0 L—
Oil5.7 L—

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Engine oilAPI CF-45.7 L

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

How many kW is the Olympian G50F3?

The Olympian G50F3 is rated 50 kW standby (62.5 kVA).

What engine is in the Olympian G50F3?

The Olympian G50F3 is powered by the Ford ESG642 engine.

What fuel does the Olympian G50F3 use?

The Olympian G50F3 runs on LP.

What is the oil capacity of the Olympian G50F3?

The Ford ESG642 engine in the Olympian G50F3 has an oil capacity of 5.7 liters.

How much coolant does the Olympian G50F3 hold?

The Olympian G50F3 cooling system holds 20 liters (5.3 US gallons) for the engine, per the manufacturer specification sheet.

What is the continuous rating of the Olympian G50F3?

The Olympian G50F3 is rated 42.5 kW prime (53 kVA), against 50 kW standby.

What voltages is the Olympian G50F3 available in?

The Olympian G50F3 is offered in 277/480 V, 120/240 V, 120/208 V, 3-phase.

Which alternator is fitted to the Olympian G50F3?

The Olympian G50F3 uses a SR4B alternator. It has 4 poles.

Available documents

Spec sheet — Olympian-G35F3S-spec-sheet (Caterpillar)Reference (Caterpillar)Reference — LECW2462-01 (Caterpillar)

This page was generated from the 3 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.