Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 2810 kW |
| Controller | DGC-2020 |
| Oil capacity | 390.0 L |
| Alternator | Marathon MAGNAMAX, MAGNAPOWER (Class H insulation) |
Engine
| Oil capacity | 390.0 L |
|---|---|
| Coolant capacity | 205.0 L |
| Displacement | 95.4 L |
| Aspiration | Exhaust turbocharging (ETC) with charge-air cooling (CAC) |
| Rated speed | 1800 rpm |
Same engine, other brands
2 brandsThe MTU 20V 4000 G83 in this set also powers 2 generator sets sold under 2 other brands. Service parts and maintenance intervals for the engine are shared; enclosure, alternator, controller and ratings are not.
| Brand | Models |
|---|---|
| Hipower | HMW 2890 T6 |
| Kohler | 2800REOZD |
Maintenance & consumables
for the MTU 20V 4000 G83| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Fuel filter | Secondary | ×1 | — | ||
| Oil filter | Spin-On | ×5 | — | ||
| Oil | 390.0 L | — |
Service specifications
1| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Temperature | Jacket water heater adjustable thermostat | 32 to 55 | °C |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Voltage reconnection
| Voltage | Phase | Connection | Leads | Notes |
|---|---|---|---|---|
| 380/400/415 | Standard scope voltage, 50 Hz (S1600/S2000/S4000) | |||
| 380/440/480 | Standard scope voltage, 60 Hz (S1600/S2000/S4000) | |||
| 400/230 | Standard scope voltage, 1600 series, 50 Hz | |||
| 440/480 | Alternator voltages, 60 Hz | |||
| 480/277 | Standard scope voltage, 1600 series, 60 Hz |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Common questions
What is the power rating of the MTU DS 2810 D6S RW?
The MTU DS 2810 D6S RW is rated 2810 kW standby.
What engine does the MTU DS 2810 D6S RW use?
The MTU DS 2810 D6S RW is powered by the MTU 20V 4000 G83 engine.
What fuel does the MTU DS 2810 D6S RW use?
The MTU DS 2810 D6S RW runs on Diesel.
What's the oil capacity on a MTU DS 2810 D6S RW?
The MTU 20V 4000 G83 engine in the MTU DS 2810 D6S RW has an oil capacity of 390.0 liters.
What is the cooling system capacity of the MTU DS 2810 D6S RW?
The MTU DS 2810 D6S RW cooling system holds 205 liters (54.2 US gallons) for the engine, per the manufacturer specification sheet.
What alternator does the MTU DS 2810 D6S RW use?
The MTU DS 2810 D6S RW uses a Marathon MAGNAMAX, MAGNAPOWER alternator. Insulation class H.