HomeMTUMTU 16V2000 DS1250

MTU 16V2000 DS1250 Generator Set

The MTU 16V2000 DS1250 is a 1250 kW (1250 kVA) Diesel standby generator set powered by a MTU 16V2000G36F engine. It is available at 380 V, 400 V and 415 V, 3-phase, 50 Hz and rated 1724 A. It holds about 102 L (26.9 gal) of oil and 70 L (18.5 gal) of coolant, with a maximum ambient rating of 40 °C. Starting uses 4 group-8 batteries rated 2800 CCA at 24 V. The set measures 4830×1990×2200 mm (190.2×78.3×86.6 in), weighs about 7100 kg (15653 lb) and produces 96.3 dBA at 7 m. The same 16V2000G36F engine also powers generator sets from Himoinsa.

1250 kW
Standby
35.7 L
Displacement
102.0 L
Oil capacity
3
Document types

How to read your MTU serial & model number →

Specifications

FuelDiesel
Frequency50.0 Hz
Standby power1250 kW
Standby kVA1250
Prime power908 kW
EmissionsTier 2
Oil capacity102.0 L
AlternatorMarathon 740RSL7182
Voltage options380 V, 400 V, 415 V
Phase3
Rated current1724 A
Power factor0.8
Battery group8D
Battery cranking2800 CCA
Battery voltage24 V
Battery quantity4
Coolant capacity70 L
Max ambient40 °C
Dimensions (L×W×H)4830×1990×2200 mm
Dry weight7100 kg
Sound level96.3 dBA @ 7 m

Engine

MTU 16V2000G36F
Oil capacity102.0 L
Coolant capacity70.0 L
Displacement35.7 L
AspirationTurbocharged and after-cooled
Rated speed1500 rpm

Maintenance & consumables

for the MTU 16V2000G36F
ItemSpecCapacityPart #Interval
Air filterMTU Air Filter (dry type), Qty 2SUA90069 PartsGeek
CoolantSystem coolant capacity (engine jacket water 70L + after cooler water 25L + balance)188.0 L
OilTotal oil system capacity114.0 L

Common questions

What is the power rating of the MTU 16V2000 DS1250?

The MTU 16V2000 DS1250 is rated 1250 kW standby (1250.0 kVA).

What engine does the MTU 16V2000 DS1250 use?

The MTU 16V2000 DS1250 is powered by the MTU 16V2000G36F engine.

What fuel does the MTU 16V2000 DS1250 use?

The MTU 16V2000 DS1250 runs on Diesel.

What is the oil capacity of the MTU 16V2000 DS1250?

The MTU 16V2000G36F engine in the MTU 16V2000 DS1250 has an oil capacity of 102.0 liters.

What alternator does the MTU 16V2000 DS1250 use?

The MTU 16V2000 DS1250 uses a Marathon 740RSL7182 alternator.

What air filter does the MTU 16V2000 DS1250 use?

The MTU 16V2000 DS1250 uses air filter part number SUA90069.

Fuel consumption

RatingLoadL/hgal/h
50%89.0
75%127.0
100%165.0
Prime
Prime50%119.9
Prime75%173.5
Prime100%231.3
Standby
Standby50%173.046.0
Standby75%261.069.0
Standby100%333.088.0

Available documents

Brochure — 16120643 PowerGeneration Solutionguide 1 2020 (MTU)Spec sheet — 1135 (MTU)Spec sheet — 231074 PG Spec 16V2000DS1250 1250kW 3D T2 60Hz (MTU)Spec sheet — 231074 PG Spec 16V2000DS1250 1250kW 3D T2 SCAQMD 60Hz (MTU)Spec sheet — 3239561 PG spec 16V2000DS1250 1135kVA 3B FC NOx 50Hz (MTU)Spec sheet — 3239611 OE spec MTU16V2000DS1250 3D 50Hz 1 15 (MTU)Spec sheet — 3239611 PG spec 16V2000DS1250 1250kVA 3D FC 50Hz (MTU)Spec sheet — 3239641 PG spec 16V2000DS1250 800kVA 3A FC 50Hz (MTU)Spec sheet — 3239761 PG spec 16V2000DS1250 1135kVA 3E FC 50Hz (MTU)Spec sheet — 3239761 PG spec 16V2000DS1250 1135kVA 3E FC NOx 50Hz (MTU)Spec sheet — EngineersGuidebook (MTU)Spec sheet — EngineersGuidebookUpdate102017 (MTU)Spec sheet — LEL Model MTU 16V2000 DS1250 Engine 16V2000C36F 1250 kW (MTU)Spec sheet — MTU 16V2000 DS1250 1250kW Prime (MTU)Spec sheet — MTU 16V2000 DS1250 1250kW Standby (MTU)Reference — MTU16V2000 (MTU)

Other sets with this engine