Home›MTU›MTU 10V1600 DS500

MTU 10V1600 DS500 Generator Set

The MTU 10V1600 DS500 is a 500 kW (500 kVA) diesel standby generator set powered by a MTU 10V 1600 G10F engine. It is available at 208 V, 240 V, 380 V, 440 V, 480 V and 600 V, 3-phase, 60 Hz and rated 1561 A. It holds about 61 L (16.1 gal) of oil and 99.3 L (26.2 gal) of coolant, with a maximum ambient rating of 50 °C. Starting uses 2 group-4 batteries rated 1050 CCA at 24 V. The set measures 3416×1873×2032 mm (134.5×73.7×80.0 in), weighs about 4175 kg (9204 lb) and produces 93.4 dBA at 7 m. An integrated tank holds 740 L (195.5 gal), roughly 9 hours of runtime.

500 kW
Standby
17.5 L
Displacement
61.0 L
Oil capacity
2
Document types

How to read your MTU serial & model number →

Typical fuel consumption for 500–505 kW Diesel generators →

Compare with other 500–505 kW Diesel generators →

Specifications

Fueldiesel
Frequency60.0 Hz
Standby power500 kW
Standby kVA500
Prime power450 kW
EmissionsEPA Tier 2
ControllerADEC
Oil capacity61.0 L
AlternatorMecc Alte HM355A3
Voltage options380 V, 400 V, 415 V
Phase3
Rated current[1561, 1353, 855, 738, 677, 541] A
Power factor0.8
Battery group4D
Battery cranking1050 CCA
Battery voltage24 V
Battery quantity2
Coolant capacity99.3 L
Max ambient50 °C
Dimensions (L×W×H)3416×1873×2032 mm
Dry weight4175 kg
Sound level88.2 dBA @ 7 m
Fuel tank740.0 L
Tank runtime9 hr

Engine

MTU 10V 1600 G10F
Oil capacity61.0 L
Coolant capacity60.0 L
Displacement17.5 L
Aspirationturbocharged
Rated speed1500 rpm

Maintenance & consumables

for the MTU 10V 1600 G10F
ItemSpecCapacityPart #Interval
Air filterMedium duty - double cartridge, two-stage dry element, replaceable element—
Fuel filterSecondary, 8 microns at 98% efficiency—
Oil filter—
Battery2 x 75 Ah, 24 V, 800 CCA minimum—
Belt—
Coolant99.3 L—
OilS10 W4068.5 L—
Spark plug—

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
FuelDiesel #2Recommended Fuel for diesel gensets (e.g. DS30, DS40, DS50, DS80, DS100, DS125, DS150, DS180, DS200, DS230, DS250, DS275, DS300, DS350, DS400, DS450, DS500)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
208V312 LEAD WYEExample from MTU 4R0063 GS30
240V112 LEADExample from MTU 4R0063 GS30 SYSTEM RATINGS connection row
240V14 LEADExample from MTU 4R0063 GS30
240V312 LEAD DELTAExample from MTU 4R0063 GS30
380V312 LEAD WYEExample from MTU 4R0063 GS30
480V312 LEAD WYEExample from MTU 4R0063 GS30
600V34 LEAD WYE DOUBLE DELTAExample from MTU 4R0063 GS30

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

How many kW is the MTU 10V1600 DS500?

The MTU 10V1600 DS500 is rated 500 kW standby (500.0 kVA).

Which engine powers the MTU 10V1600 DS500?

The MTU 10V1600 DS500 is powered by the MTU 10V 1600 G10F engine.

What kind of fuel does the MTU 10V1600 DS500 run on?

The MTU 10V1600 DS500 runs on diesel.

What is the oil capacity of the MTU 10V1600 DS500?

The MTU 10V 1600 G10F engine in the MTU 10V1600 DS500 has an oil capacity of 61.0 liters.

What is the cooling system capacity of the MTU 10V1600 DS500?

The MTU 10V1600 DS500 cooling system holds 99.3 liters (26.2 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

What is the continuous rating of the MTU 10V1600 DS500?

The MTU 10V1600 DS500 is rated 450 kW prime (450 kVA), against 500 kW standby.

What is the sound level of the MTU 10V1600 DS500?

The MTU 10V1600 DS500 is rated at 88.2 dBA at 7 m, per the manufacturer specification sheet.

How much does the MTU 10V1600 DS500 weigh?

The MTU 10V1600 DS500 has a dry weight of 4175 kg (9204 lb).

How big is the fuel tank on the MTU 10V1600 DS500?

The MTU 10V1600 DS500 has a 740 liter (195 US gallon) fuel tank, giving about 9 hours of runtime.

What voltage does the MTU 10V1600 DS500 produce?

The MTU 10V1600 DS500 is offered in 380 V, 400 V, 415 V, 3-phase.

How many cold cranking amps does the MTU 10V1600 DS500 require?

The MTU 10V1600 DS500 uses 2 batteryies, 24 V each, 1050 CCA, group 4D, per the manufacturer specification sheet.

Which alternator is fitted to the MTU 10V1600 DS500?

The MTU 10V1600 DS500 uses a Mecc Alte HM355A3 alternator.

Fuel consumption

RatingLoadL/hgal/h
Prime115.030.38
Prime50%30.48.03
Prime75%42.511.23
Prime100%56.114.82
Standby50%5.21.4
Standby75%7.52.0
Standby100%9.92.6

Available documents

Spec sheet — 23553 PG Spec 10V1600DS500 500kVA 3D FC 50Hz (MTU)Spec sheet — 23554 PG Spec 10V1600DS500 450kVA 3B FC 50Hz (MTU)Spec sheet — 23555 PG Spec 10V1600DS500 450kVA 3B EO 50Hz (MTU)Spec sheet — 23561 PG Spec 10V1600DS500 500kW 3D T2 60Hz (MTU)Spec sheet — 23561 PG Spec 10V1600DS500 500kW 3D T2 SCAQMD 60Hz (MTU)Spec sheet — 23562 PG Spec 10V1600DS500 450kW 3B T2 60Hz (MTU)Spec sheet — 3237931 PG spec 10V1600DS500 460kVA 3B NOx 50Hz (MTU)Spec sheet — 3238011 PG spec 10V1600DS500 507kVA 3D 50Hz (MTU)Spec sheet — EngineersGuidebook (MTU)Spec sheet — EngineersGuidebookUpdate102017 (MTU)Spec sheet — MTU-Engineers-Guidebook-2014 (MTU)Spec sheet — MTU10V1600DS500 450kW Prime (MTU)Spec sheet — MTU 10V1600 DS500 450kVA Prime (MTU)Spec sheet — MTU 10V1600 DS500 500kW Standby (MTU)Spec sheet — xyz-sample mtu-10V1600-DS500 572RSL4027 50°C-122°F 20210908153314 (MTU)Reference — Diesel-Brochure-S1600-New (MTU)

This page was generated from the 16 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.