Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 550 kW |
| Standby kVA | 687 |
| Prime power | 500 kW |
| Emissions | EPA Certified |
| Controller | Inteligen |
| Oil capacity | 48.0 L |
| Alternator | Marathon Magna Max |
| Voltage options | 120/208 V, 277/480 V |
| Phase | 3 |
| Power factor | 0.8 |
| Battery cranking | 900 CCA |
| Battery voltage | 24 V |
| Coolant capacity | 60 L |
| Dimensions (L×W×H) | 6045×2438×3810 mm |
| Fuel tank | 3028.0 L |
Engine
| Oil capacity | 48.1 L |
|---|---|
| Coolant capacity | 67.0 L |
| Displacement | 16.12 L |
| Aspiration | Turbocharged, Charge Air-Cooled |
| Rated speed | 1800 rpm |
Maintenance & consumables
for the Volvo Penta TAD1642GE| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | — | 1000 hr | find | ||
| Fuel filter | — | 500 hr | find | ||
| Oil filter | — | 1000 hr | find | ||
| Belt | — | 1000 hr | find | ||
| Coolant | 60.0 L | — | 500 hr | ||
| Oil | 48.0 L | — | 100 hr |
Compatible filters for the Volvo Penta TAD1642GE — cross-referenced via Donaldson. Options to verify against your serial number, not confirmed for this exact unit.
- Fuel filter: Donaldson P552040 Ac Delco TP985
- Fuel filter (primary): Donaldson P552040 Ac Delco TP985
Common questions
What is the power rating of the MQ Power EGC-550V?
The MQ Power EGC-550V is rated 550 kW standby (687.0 kVA).
What engine does the MQ Power EGC-550V use?
The MQ Power EGC-550V is powered by the Volvo Penta TAD1642GE engine.
What fuel does the MQ Power EGC-550V use?
The MQ Power EGC-550V runs on Diesel.
What is the oil capacity of the MQ Power EGC-550V?
The Volvo Penta TAD1642GE engine in the MQ Power EGC-550V has an oil capacity of 48.1 liters.
What alternator does the MQ Power EGC-550V use?
The MQ Power EGC-550V uses a Marathon Magna Max alternator.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| 25% | 38.2 | 10.1 | |
| 50% | 68.5 | 18.1 | |
| 75% | 101.4 | 26.8 | |
| 100% | 142.7 | 37.7 |