Home›Magnum›Magnum MMG100C Super Start

Magnum MMG100C Super Start Generator Set

The Magnum MMG100C Super Start is a 94 kW (117 kVA) standby generator set powered by a Cummins/Onan QSB5-G3 NR3 engine. It is available at 120 V, 139 V, 208 V, 220 V, 240 V and 277 V, ['1Ø', '3Ø'] and 60 Hz. It holds about 15.5 L (4.1 gal) of oil and 22 L (5.8 gal) of coolant. Starting uses 1 group-24 battery rated 800 CCA at 12 V. The set weighs about 1475 kg (3252 lb) and produces 68 dBA. An integrated tank holds 147 L (38.8 gal), roughly 22 hours of runtime. The same QSB5-G3 NR3 engine also powers generator sets from Cummins/Onan and Terex.

94 kW
Standby
4.5 L
Displacement
15.5 L
Oil capacity
0
Document types

Service parts for the MMG100C Super Start

Grouped by system, with how many of each the parts manual calls for.

Air intake

1 required
100-001Air filtersee priceAmazon

Fuel system

1 required
100-003Fuel filtersee priceAmazon

Oil system

1 required
100-002Oil filtersee priceAmazon

Belts

1 required
100-005Belt$8.98eBay

Cooling system

1 required
100-004Coolant filtersee priceAmazon

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

Frequency60.0 Hz
Standby power94 kW
Standby kVA117
Prime power82 kW
ControllerMagnum Digital (MDC)
Oil capacity15.5 L
AlternatorMarathon 362PSL1606
Voltage options120 V, 139 V, 208 V, 220 V, 240 V, 277 V
Phase1Ø,3Ø
Power factor[1, 0.8]
Circuit breaker400 A
Battery groupGroup 24
Battery cranking800 CCA
Battery voltage12 V
Battery quantity1
Coolant capacity22.0 L
Dry weight1475 kg
Sound level68.0 dBA
Fuel tank147.0 L
Tank runtime22 hr

Engine

Cummins/Onan QSB5-G3 NR3
Oil capacity12.1 L
Displacement4.5 L
AspirationTurbocharged and air-to-air aftercooled
Rated speed1800 rpm

Same engine, other brands

2 brands

The Cummins/Onan QSB5-G3 NR3 in this set also powers 2 generator sets sold under 2 other brands. Service parts and maintenance intervals for the engine are shared; enclosure, alternator, controller and ratings are not.

BrandModels
Cummins/OnanDSFAE
TerexT120C

Maintenance & consumables

for the Cummins/Onan QSB5-G3 NR3
ItemSpecCapacityPart #Interval
Air filterAir Filter100-001 Amazon Amazon eBay eBay
Fuel filterFuel Filter100-003 Amazon eBay
Oil filterOil Filter100-002 Amazon eBay
Battery—
BeltBelt100-005 Amazon Amazon eBay $8.98 eBay NAPA $34.86
Coolant—
Coolant filterCoolant Filter100-004 Amazon Amazon eBay
Oil—
Spark plug—

Common questions

How many kW is the Magnum MMG100C Super Start?

The Magnum MMG100C Super Start is rated 94 kW standby (117.0 kVA).

What engine does the Magnum MMG100C Super Start use?

The Magnum MMG100C Super Start is powered by the Cummins/Onan QSB5-G3 NR3 engine.

What is the oil capacity of the Magnum MMG100C Super Start?

The Cummins/Onan QSB5-G3 NR3 engine in the Magnum MMG100C Super Start has an oil capacity of 12.1 liters.

What is the coolant capacity of the Magnum MMG100C Super Start?

The Magnum MMG100C Super Start cooling system holds 22 liters (5.8 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

What is the prime power rating of the Magnum MMG100C Super Start?

The Magnum MMG100C Super Start is rated 82 kW prime (102 kVA), against 94 kW standby.

How loud is the Magnum MMG100C Super Start?

The Magnum MMG100C Super Start is rated at 68.0 dBA, per the manufacturer specification sheet.

How much does the Magnum MMG100C Super Start weigh?

The Magnum MMG100C Super Start has a dry weight of 1475 kg (3251 lb).

What size fuel tank does the Magnum MMG100C Super Start have?

The Magnum MMG100C Super Start has a 147 liter (39 US gallon) fuel tank, giving about 22 hours of runtime.

What voltages is the Magnum MMG100C Super Start available in?

The Magnum MMG100C Super Start is offered in 120 V, 139 V, 208 V, 220 V, 240 V, 277 V, 1Ø,3Ø-phase.

How many cold cranking amps does the Magnum MMG100C Super Start require?

The Magnum MMG100C Super Start uses 1 battery, 12 V each, 800 CCA, group Group 24, per the manufacturer specification sheet.

What alternator comes on the Magnum MMG100C Super Start?

The Magnum MMG100C Super Start uses a Marathon 362PSL1606 alternator.

Which oil filter part number does the Magnum MMG100C Super Start take?

The Magnum MMG100C Super Start uses oil filter part number 100-002.

What fuel filter fits the Magnum MMG100C Super Start?

The Magnum MMG100C Super Start uses fuel filter part number 100-003.

What air filter does the Magnum MMG100C Super Start use?

The Magnum MMG100C Super Start uses air filter part number 100-001.

Troubleshooting

32

Fault codes

CodeMeaningCauseRemedy
3Battery Flat — If the controller switches off during starting sequence due to bad battery condition, it doesn't try to start again and activates this protection.
4Binary Input — Configurable warning/shutdown alarms on the inputs of IL-NT.
5ChrgAlternFail — Failure of the alternator to charge the battery.
6EmergencyStop — If the input Emergency Stop is opened (pushed in), shutdown is immediately activated.
7Engine Temp Sd — Water temperature is greater than Sd Water Temp setpoint.
8Engine Temp Wrn — Water temperature is greater than Wrn Water Temp setpoint.
9Fgen<, > — The generator frequency is out of limits given by Gen >f and Gen <f setpoints.
10Fuel Level Sd — Fuel level is smaller than Sd Fuel Level setpoint.
11Fuel Level Wrn — Fuel level is smaller than Wrn Fuel Level setpoint.
12GCB fail — Failure of the generator circuit breaker.
13Igen unbl — The generator current is unbalanced.
14Low BackupBatt — RTC backup battery is flat.
15Oil Press Sd — Oil pressure is smaller than Sd Oil Press setpoint.
16Oil Press Wrn — Oil pressure is smaller than Wrn Oil Press setpoint.
17Overload — The load is greater than the value given by Overload setpoint.
18Overspeed — The protection comes active if the speed is greater than Overspeed setpoint.
19ParamFail — Wrong checksum of parameters. Happens typically after downloading new firmware or changing of the parameter. The controller stays in INIT mode.Wrong checksum of parameters; happens typically after downloading new firmware or changing of the parameter.Check all parameters write at least one new parameter.
20PickupFault — Failure of the magnetic pick-up sensor for speed measurement.
21Sd IOM fail — IOM/IGS-PTM module.
22SprinkIActive — The protection is active if the output Sprinkler is closed.
23Start failed — Gen-set start failed.
24Stop fail — Gen-set stop failed.
25Ubat — Battery voltage is out of limits given by Batt Overvolt and Batt Undervolt setpoints.
26Underspeed — During starting of the engine, when the RPM reaches the value of Starting RPM setpoint, the starter is switched off and the speed of the engine can drop under Start RPM again. Then the underspeed protection becomes active. Protection evaluation starts 5 seconds after start up.
27Vgen<, > — The generator voltage is out of limits given by Gen <V and Gen <V setpoints.

Symptoms & remedies

SymptomCauseRemedy
Low Fuel Level ShutdownFuel level low; fuel tank leak or tank running dry; fuel level sender and connecting wiring damaged.Check the fuel level on the LCD window and confirm the generator is sitting level; check for leaks in the fuel tank; check the fuel level sender and the connecting wiring for damage and check for continuity between the sender and the engine controller.
Low Oil Pressure ShutdownEngine oil level low; oil leaks; loss of oil pressure; oil pressure sender fault.Check the level of the engine oil with the dipstick and add oil if required; visually inspect the engine for oil leaks; restart the unit and verify the loss of oil pressure, shutting the engine down immediately if the oil pressure value does not read 5 psi (34 kPa) within five seconds; check the oil pressure sender and refer to the troubleshooting section of the engine operation and maintenance manual.
Low Coolant Level ShutdownCoolant level low; visible leaks in coolant hoses, engine block or water pump; coolant mixed with engine oil.Allow the engine to cool; check the coolant level in the radiator and add coolant until it is 3/4" below the filler neck, then secure the radiator cap; inspect coolant hoses, engine block and water pump for visible leaks; check engine oil to verify no coolant has mixed with it and consult the ENGINE OPERATION & MAINTENANCE MANUAL.
High Coolant Temperature ShutdownCoolant level low; radiator shroud and ducting blockage; visible leaks in coolant hoses, engine block or water pump; loose serpentine drive belt for the water pump; engine overheating.Check the coolant level in the overflow jug; restart the engine and read the coolant temperature, stopping the engine immediately if the coolant temperature is 230°F (110°C) or more; allow the engine to cool, add coolant to the overflow jug if low and check the radiator level, adding coolant until it is 3/4" below the filler neck; check the radiator shroud and ducting for blockage and remove any foreign matter; inspect coolant hoses, engine block and water pump for visible leaks; check the tension of the serpentine drive belt for the water pump; if no other problems are found, remove the load on the generator and restart the engine, checking the coolant temperature and shutting the engine down immediately if it starts to overheat, and consult the engine operation and maintenance manual.
Overcrank ShutdownFuel level low; fuel pump not operating properly; air filter blockage; engine will not start.Check the fuel level in the tank; check for proper operation of the fuel pump; check air filter for blockage; if the engine will not start, consult the ENGINE OPERATION AND MAINTENANCE MANUAL for additional information on troubleshooting starting problems.
Overspeed or Underspeed ShutdownFrequency above or below 60.0 Hz with no loads on the generator, requiring engine speed adjustment.Disconnect all loads and restart the generator, read the frequency (Hz) on the LCD display (should read 60.0 Hz with no loads); if the frequency is above or below 60.0 Hz, adjust the engine speed — see the engine manual for throttle adjustments on mechanical governed units and the electronic governor manual for electronically controlled units.
Wet StackingDiesel engine run at less than 35% of its full load capacity, causing unburned fuel to accumulate in the exhaust system; can also cause fouling of injectors and buildup on engine valves.Load the unit heavily for five hours or until the exhaust is clear; diesel engines operate properly when applied loads are between 35% and 100% capacity.

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Parts

11
Part #DescriptionQtySystem
100-001Air Filter1Air filter Amazon Amazon eBay eBay
100-002Oil filter1Oil filter Amazon eBay
100-003Fuel filter1Fuel filter Amazon eBay
100-004Air Filter1Air filter Amazon Amazon eBay
100-005Air Filter Element1Air filter Amazon Amazon eBay $8.98 eBay NAPA $34.86
100-006Spark Plug1Spark plug Amazon eBay
100-007Battery1Battery Amazon eBay KuduParts $153.00
100-008Bolt (M12-1.75)1Bolt m12 1 75 Amazon eBay
125550Oil FilterOil filter Amazon eBay
125551Fuel FilterFuel filter Amazon eBay
125561Air Filter - PrimaryAir filter Amazon eBay

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
Prime6.324.0
Standby6.324.0

Available documents

Full service, cheapest listings

Priced items from this model's own parts manual.

Belt 100-005$8.98
1 priced item$8.98