Home›Kohler›Kohler 50EFOZD

Kohler 50EFOZD Generator Set

The Kohler 50EFOZD is a 50 kW (62.5 kVA) diesel standby generator set. It is available at 115/230 V, 110/190 V, 110/220 V, 220/380 V, 230/400 V and 240/416 V, single-phase, 50 Hz and rated 196 A. It holds about 14 L (3.7 gal) of oil and 14 L (3.7 gal) of coolant. Starting uses battery rated 625 CCA at 12 V. The set measures 1690×767×1015 mm (66.5×30.2×40.0 in) and weighs about 1087 kg (2396 lb).

50 kW
Standby
14.0 L
Oil capacity
5
Document types

How to read your Kohler serial & model number →

Typical fuel consumption for 50–55 kW Diesel generators →

Compare with other 50–55 kW Diesel generators →

Service parts for the 50EFOZD

Grouped by system, with how many of each the parts manual calls for.

Air intake

1 required
226915Air filter$43.43eBay

Fuel system

2 required
GM48727Fuel filter$24.99eBay
GM50263Fuel filter (primary)$99.99eBay

Oil system

1 required

Belts

1 required
GM15402Belt$34.50eBay

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

Fueldiesel
Frequency50.0 Hz
Standby power50 kW
Prime power50 kW
EmissionsEPA Tier II
Controller550, Decision-Maker, Decision-Maker 3+, Decision-Maker 3500
Oil capacity14.0 L
AlternatorFast-Response X (Class Class H insulation)
Voltage options115/230 V, 110/190 V, 110/220 V, 220/380 V, 230/400 V, 240/416 V
Phase1 and 3
Rated current196 A
Battery cranking625 CCA
Battery voltage12- or 24-volt V
Coolant capacity14 L
Dimensions (L×W×H)1690×767×1015 mm
Dry weight1087 kg
Wet weight1114 kg

Filters & service parts

model family
ItemSpecCapacityPart #Interval
Air filter226915250 hr Amazon eBay $43.43
Fuel filterGM48727500 hr Amazon eBay $24.99
Fuel filterIncludes primary and secondary fuel filter elementGM50263500 hr Amazon eBay $99.99
Oil filterGM32809250 hr Amazon Amazon Amazon Amazon eBay $26.25 NAPA $28.76
Battery—500 hr
BeltGM15402 Amazon eBay $34.50
Coolant50% ethylene glycol and 50% clean, softened water—2000 hr
Coolant filter—
Oil—250 hr
Spark plug—

Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.

Service intervals

28
ItemActionHoursMonthsNotes
Generator end bracket bearingReplace10 hrService more frequently if bearing inspection indicates excessive rotor end play or bearing damage from corrosion or heat buildup
Electrical connectionsCheck50 hr1 moCheck and tighten; Monthly or 50 Hrs.
Siphon break function, if equippedTest100 hr3 mo3 Months or 100 Hrs.
Air cleaner elementInspect250 hr6 moClean or replace as necessary; 6 Months or 250 Hrs.
Coolant temperature protection levelCheck250 hr6 mo6 Months or 250 Hrs.
Engine oilChange250 hr6 moFirst service — First 50 Hrs., then every 250 Hrs. or 6 months
Exhaust/water mixing elbowClean250 hr6 mo6 Months or 250 Hrs.
Oil filter(s)Replace250 hr6 moFirst service — First 50 Hrs., then every 250 Hrs. or 6 months; more frequent in dusty areas
Seawater pump impellerCheck250 hr6 mo6 Months or 250 Hrs.
Zinc plugsReplace250 hr6 moInspect and replace; 6 Months or 250 Hrs.
Battery cablesClean500 hr12 moYearly or 500 Hrs.
Cooling systemCheck500 hr12 moYearly or 500 Hrs.
Crankcase vent filter, if equippedReplace500 hr12 moYearly or 500 Hrs.
Crankcase ventilation system, if equippedClean500 hr12 moYearly or 500 Hrs.
Fuel filter elementsReplace500 hr12 moYearly or 500 Hrs.
Heat exchanger core and aftercooler core, if equippedClean500 hr12 moInspect and clean; Yearly or 500 Hrs.
Seawater pump impellerReplace500 hr12 moYearly or 500 Hrs.
Cooling systemChange2000 hr24 moFlush and refill; 2 years or 2000 Hrs.
Cooling systemTest2000 hr24 moPressure test; 2 years or 2000 Hrs.
Seawater pumpInspect2000 hr24 moInspect and repair; 2 years or 2000 Hrs.
ThermostatsTest2000 hr24 mo2 years or 2000 Hrs.
BeltCheck1 moMonthly; replace as necessary
Circuit breakers, fusesTest1 moMonthly
Crankcase breatherInspect3 moQuarterly
Fuel pipingInspect12 moYearly
Generator set storage (three months or longer)Other3 moPerform the storage procedure before taking a generator set out of service for three months or longer
Return lines for obstructionsInspect12 moYearly
Seawater pumpOtherFirst service — Prime the seawater pump before initial startup; confirm water discharge from the exhaust outlet

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

60
TypeItemValueUnitCondition
ClearanceEnd bracket to bearing outer race clearance6.35 mm (0.25 in.)mm (in.)
ClearanceExhaust line downward pitch13mm per 30.5 cmminimum; 1/2 in. per running foot
ClearanceExhaust outlet height above waterline10cmminimum; 4 in.; craft loaded to maximum capacity
ClearanceGenerator set clearance on all sides without sound shield38mmminimum; 1.5 in.; top, front, rear, and sides
ClearanceMaximum distance between silencer and exhaust mixer elbow3m10 ft.
ClearanceMaximum distance between silencer and exhaust outlet1.5m5 ft.
ClearanceMaximum seawater pump lift3m10 ft.
ClearanceMaximum silencer vertical lift1.2m4 ft.
ClearanceSiphon break height above waterline31cmminimum; 1 ft.; required if exhaust manifold outlet is less than 23 cm (9 in.) above waterline
ClearanceSound shield left-rear and front door clearance305mmminimum; 12 in.; intake and discharge openings
GapMagnetic pickup air gap0.35--0.71 mm (0.014--0.028 in.)mm (in.)1/4 to 1/2 turn back from ring gear tooth contact
GapSpeed sensor air gap0.36--0.71 mm (0.014--0.028 in.)mm (in.)
OtherAlternator protection rated current vs. time delay200%: 40 seconds; 300%: 10 seconds; 425%: 5 seconds; 950%: 1 second% rated current / seconds
OtherAlternator short-circuit excitation currentUp to 300% at 60 Hz (approximately 275% at 50 Hz) for a minimum of 10 seconds% rated current / seconds
OtherAngular limits during operation, continuous / intermittent (3 min or less)20 / 30degrees40EOZD(C)J, 33EFOZD(C)J
OtherAngular limits during operation, continuous / intermittent (3 min or less)25 / 35degrees125/150EOZD(C)J, 100/125EFOZD(C)J
OtherAngular limits during operation, continuous / intermittent (3 min or less)35 / 45degrees50EFOZD(C)J, 55/65EOZD(C)J, 45/55EFOZD(C)J, 80/99EOZD(C)J, 70/80EFOZD(C)J
OtherController power drain400 milliamps at 12V; 200 milliamps at 24VmA
OtherCyclic cranking (default) and maximum15 seconds cranking, 15 seconds rest, 3 cycles (default); up to 30 s crank, up to 60 s rest, up to 6 cyclesseconds/cycles
OtherDigital inputs inhibit period after startup30seconds
OtherFuel line ID size9.7mm3/8 in.; customer-supplied
OtherFuel pump lift for 200/175 model groups3m10 ft.
OtherFuel pump lift for 40/33 and 40/50 model groups3m10 ft.
OtherFuel pump lift for 55--150 model groups2.4m7.9 ft.
OtherLoad profile minimum / ideal30% (minimum); 70% load or more (ideal)% load
OtherOil pressure shutdown delay after low pressure detected5seconds
PressureCombustion air intake restriction25in. H2Omaximum; 6.25 kPa; models 40--200EOZDJ/EOZCJ and 33--175EFOZDJ/EFOZCJ
PressureLow oil pressure switch 25332315 ±3psi
PressureLow oil pressure switch 32830915 ±2psi
PressureLow seawater pressure switch GM302630.5 ±0.3psi
PressureMaximum allowable exhaust back pressure7.5kPaunder all engine loading conditions; 30 in. H2O
PressureMaximum seawater inlet pressure at seawater pump34.5kPaat rest and underway at all speeds; 5 psi
PressureOil pressure sender 264390240 +17 --15 ohms at 0 psi; 153 +12 --15 ohms at 25 psi; 33.5 ohms at 100 psiohms
PressureOil pressure sender GM16788 input pressure range0--1034 kPa (0--150 psi)kPa (psi)proof pressure 3103 kPa (450 psi); burst pressure 5171 kPa (750 psi)
ResistanceAlternator field insulation (megohmmeter, 500 VDC applied to F+ or F-- lead and rotor shaft)500 kOhms (1/2 megohm) and higherkOhms500 volts DC applied
ResistanceAlternator field resistance (F+/F--)1.44ohms
ResistanceAlternator field resistance (F+/F--)1.6ohms
ResistanceAlternator field resistance (F+/F--)1.79ohms
ResistanceAlternator field resistance (F+/F--)1.9ohms
ResistanceAlternator field resistance (F+/F--)2.21ohms
ResistanceAlternator field resistance (F+/F--)2.7ohms
ResistanceExciter armature resistance0.11ohms
ResistanceExciter armature resistance0.34ohms
ResistanceExciter armature resistance0.47ohms
ResistanceGovernor actuator coil resistance, 12 VDC2.05 ±0.25ohmsambient temperature
ResistanceGovernor actuator coil resistance, 24 VDC7.20 ±0.50ohmsambient temperature
ResistanceGovernor actuator coil to case isolation>3megohms
SpeedFull load engine speed1800 rpm (60 Hz) or 1500 rpm (50 Hz)rpmhot engine under load
SpeedOverfrequency setting range, delay and default102%- 140% of nominal (range); 10 (delay); 110% of nominal (default)% of nominal / sec.
SpeedRPM of Droop1.7Hz50 rpm; ECU governor droop setting
SpeedUnderfrequency setting range, delay and default80%- 95% of nominal (range); 10 short term, 60 long term (delay); 90% of nominal (default)% of nominal / sec.
TemperatureController operating temperature- 40 to 70CDecision-Maker 3500 controller
TemperatureCoolant 50% ethylene glycol freezing / overheating protection- 37 (- 34 F) freezing; 129 (265 F) overheatingC50% ethylene glycol solution
TemperatureCoolant temperature sender GM39458, Value A123.8 +7.2 --7.8ohms at 195°F
TemperatureCoolant temperature sender GM39458, Value B35.6 +3.4 --3.6ohms at 280°F
TemperatureExhaust temperature switch 249872 / GM19189, close102°C±15°C (215°F±5°F)°C (°F)
TemperatureExhaust temperature switch 249872 / GM19189, open88°C±15°C (190°F±10°F)°C (°F)
TemperatureHigh coolant temperature switch 241481 / GM29288103°C ±4°C (218°F ±7°F)°C (°F)normally open, closes on temperature rise
TemperatureHigh intake air temperature shutdown delay5secondsafter intake air reaches shutdown range
TorqueAlternator adapter to flywheel housing bolts, 180 kW, 7/16--14 grade 8 bolt85 (63)Nm (ft. lb.)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Coolant50% ethylene glycol and 50% clean, softened waterabove -37°CProvides freezing protection to - 37 C (- 34 F) and overheating protection to 129 C (265 F). Less than 50% ethylene glycol may not provide adequate protection; more than 50% can cause engine or component damage. Do not use alcohol or methanol antifreeze. See spec sheet for coolant capacity.
Engine oilOil suited to the climateUse oil with a viscosity suitable for the operating climate; refer to engine operation manual.
Fuel#2 diesel fuelDiesel-fueled engines: fill the fuel tank with #2 diesel fuel and condition the fuel system with compatible additives to control microbial growth.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Fault codes

15
CodeNameMeaningSeverityAction
E0Controller memory failureGovernor controller memory failure (load share model display code).ShutdownReplace governor controller.
E1Loss of remote speed potentiometer signalGovernor controller has lost the remote speed potentiometer signal.WarningCheck the remote speed potentiometer and its wiring.
E2Overspeed detectedOverspeed detected by the governor controller (load share model display code).ShutdownGovernor controller must be turned off and reset to allow an engine restart.
E3Actuator drive overcurrent detectedActuator drive overcurrent detected by the governor controller (load share model display code).ShutdownCheck wiring. Check actuator loading and linkage.
Emergency StopEmergency Stop Shutdown (550 controller)The local or optional remote emergency stop switch activated.ShutdownCorrect the cause and reset the emergency stop switch, then reset the controller.
Hi Cool Temp ShutdownHigh Coolant Temperature Shutdown (550 controller)Engine coolant temperature reached the shutdown range; shutdown occurs 5 seconds after the engine reaches the temperature shutdown range (30 second inhibit after startup).ShutdownAllow the engine to cool and troubleshoot the cooling system.
Low Coolant LevelLow Coolant Level Shutdown (550 controller)Low coolant level detected; shutdown occurs 5 seconds after low coolant level is detected (30 second inhibit after startup).ShutdownRestore the coolant to the normal operating level and check for leaks.
Oil Pressure ShutdownLow Oil Pressure Shutdown (550 controller)Low oil pressure condition detected; shutdown occurs 5 seconds after the low pressure condition is detected (30 second inhibit after startup).ShutdownCheck the engine oil level and lubrication system.
Over CrankOvercrank Shutdown (550 controller)The unit does not start within the defined cranking period. Range 0--6 cycles; default 3 cycles with 15 sec crank and 15 sec rest.ShutdownCheck fuel supply, starting system, and speed sensor circuitry.
Over CurrentOvercurrent Warning (550 controller)The generator set supplies more than 110% of the rated standby output current for more than 10 seconds.WarningReduce the electrical load and check for faults in the load circuit.
Over SpeedOverspeed Shutdown (550 controller)Governed frequency on 50 and 60 Hz models exceeds the overspeed setting for 0.25 seconds. Setting range 65--70 Hz (60 Hz) / 55--70 Hz (50 Hz); default 70 Hz.ShutdownCheck governor and engine speed; reset the controller after correcting the cause.
Over VoltageOvervoltage Shutdown (550 controller)Voltage exceeds the overvoltage setting for the time delay period. Range 105%--135% of nominal; default 115% at 2 seconds.ShutdownTroubleshoot the voltage regulator and sensing circuits.
SPN 29Throttle input fault codeThrottle input fault code referenced for 55--200EOZD(C)J and 40--175EFOZD(C)J models.WarningConfirm throttle input settings against factory defaults in Section 9.9.1.
SPN 91Throttle input fault codeThrottle input fault code referenced for 55--200EOZD(C)J and 40--175EFOZD(C)J models.WarningConfirm throttle input settings against factory defaults in Section 9.9.1.
Under VoltageUndervoltage Shutdown (550 controller)Voltage falls below the undervoltage setting for the time delay period. Range 70%--95% of nominal; default 85% at 10 seconds.ShutdownCheck alternator output, load, and voltage regulator.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Droop Settings adjustment

⚠ Kohler SiteTech is needed to power the ECU on these generator set models.

  1. Select the Governors tab and open the RPM of Droop drop-down list.
  2. Select 1.7 Hz (50 rpm).
  3. If reprogramming, select Program when linked to a powered ECU.
ECU Parameter Settings (55--200EOZD(C)J and 40--175EFOZD(C)J Models) adjustment

⚠ Setup and adjustments of the ECU only by an authorized Kohler distributor/dealer; settings are password protected.

Tools: John Deere Service Advisor software, laptop, Internet connection

  1. Login to John Deere Service Advisor software with user name and password; click Sign In.
  2. Click the I Agree button.
  3. Click the Jobs icon.
  4. Open an existing job or click Start a New Job.
  5. Enter a job name and click Next.
  6. Enter the engine model and click the search button.
  7. Enter the Engine Serial Number and click Use this Model.
  8. Click Finish.
  9. Click Reprogramming.
  10. Check the ENGINE box to activate the Action drop-down list.
  11. Select Download Selected Payload(s) and click Go.
  12. Select Reprogramming current ECU and click Done.
  13. After status changes to Downloaded, click Back.
  14. Check ENGINE, select Start Reprogramming, and click Go.
  15. Acknowledge notices and open the ECU parameters window.
Magnetic Pickup Adjustment adjustment
  1. Place the generator set master switch in the OFF/RESET position.
  2. Verify the flywheel is not rotating. Loosen the jam nut.
  3. Turn in the magnetic pickup until the pole face bottoms on the ring gear tooth.
  4. Back out the magnetic pickup 1/4 to 1/2 turn providing a 0.35--0.71 mm (0.014--0.028 in.) air gap.
  5. Tighten the jam nut without moving the magnetic pickup.
Throttle Input Settings adjustment

⚠ Kohler SiteTech is needed to power the ECU on these generator set models.

  1. Select the Speed Control tab.
  2. Ensure Disable All Throttle is checked; all throttle selections become disabled.
  3. If reprogramming, select Program when linked to a powered ECU.
Twelve-Lead Reconnection adjustment

⚠ Affix voltage reconnection decal 246242 after reconnecting to a voltage different from the nameplate.

  1. Place the generator start/stop switch in the STOP position.
  2. Disconnect generator set engine starting battery, negative (--) lead first.
  3. Disconnect power to battery charger, if equipped.
  4. Use Figure 8-3 to determine voltage configuration and reconnect leads as needed; route CT leads per diagram.
Volt/Hz Potentiometer Adjustment adjustment

Tools: 100-watt light bulb, voltmeter, frequency meter

  1. Turn the generator set master switch to OFF/RESET.
  2. Make the single- or three-phase sensing selection at switch #2.
  3. Turn the stability potentiometer fully counterclockwise.
  4. Connect a 100-watt light bulb across terminals V0 and V7 on the controller terminal strip.
  5. Start the generator set and adjust the stability potentiometer until minimum light bulb flicker is obtained.
  6. Make the frequency selection (50 or 60 Hz) at switch #1.
  7. Select the bias switch for No Bias Input.
  8. Adjust engine speed to the desired cut-in frequency (57.5--58.0 Hz for 60 Hz models or 47.5--48.0 Hz for 50 Hz models).
  9. Rotate the volts/Hz adjustment potentiometer clockwise until voltage begins to drop.
  10. Adjust engine speed to obtain full load engine speed of 1800 rpm (60 Hz) or 1500 rpm (50 Hz).
Controller Resetting (550 Controller, Following System Shutdown or Warning) diagnostic

⚠ Read the Safety Precautions and Instructions section before proceeding.

  1. Move the generator set master switch to the AUTO position if not already done.
  2. Silence the alarm horn by pressing the alarm off key.
  3. Disconnect the generator set load using the line circuit breaker or automatic transfer switch.
  4. Correct the cause of the fault shutdown or warning.
  5. Start the generator set by moving the master switch to OFF/RESET and then to RUN.
  6. Test operate the generator set to verify correction of the shutdown cause.
  7. Move the master switch to OFF/RESET to stop the generator set.
  8. Move the master switch to the AUTO position.
  9. Silence the alarm horn by pressing the alarm off key.
  10. Reconnect the generator set load via the line circuit breaker or automatic transfer switch.
LED Circuit Board (Flashlight) Test diagnostic

⚠ Do not expose the photo transistor circuit board to any external light source; exposure to light causes high voltage. Place black electrical tape over the LED before starting the set.

Tools: flashlight, voltmeter

  1. Remove the junction box panels from the generator end and remove the photo transistor board/LED board cover.
  2. With the generator set running at no load, shine a flashlight on the exposed photo transistor board.
  3. Observe the AC output voltmeter; high AC output voltage indicates the SCR assembly and photo transistor board are functioning.
  4. With the set running, approximately 1--2 volts DC should be observed at 3B (+) and 5B (--) at the LED board; the reading should drop when the flashlight is applied.
Speed Sensor Test with Generator Set Running diagnostic

⚠ Controller leads must remain connected to the speed sensor terminals during the test; slide leads only enough to expose connection for test leads.

Tools: DC voltmeter

  1. With the master switch in OFF/RESET, connect a DC voltmeter between the positive (+) lead (wire 24) and ground (wire 2); reading should be approximately 8--12 VDC.
  2. Place the master switch in the RUN position to start the generator set.
  3. With the set running, place the voltmeter negative probe on the 0 terminal (wire 16, white) and positive probe on the positive (+) terminal (wire 24, red); reading should be approximately 7--12 VDC.
  4. Place the master switch in OFF/RESET to stop the generator set.
  5. If a signal is present, check continuity of wires 2, 16, and 24 between the controller P1 connector and the speed sensor leads.
Speed Sensor Test with Separate 12 VDC Source diagnostic

Tools: DC voltmeter, 12-volt battery or DC power supply, flat piece of iron or steel

  1. Place the generator set master switch in the OFF/RESET position.
  2. Disconnect the speed sensor leads.
  3. Connect the speed sensor, DC voltmeter, and DC voltage source as shown in the manual.
  4. Touch the sensing surface with a flat piece of iron or steel at least 4.1 cm (1/4 cu. in.) in size.
  5. The DC voltmeter reading should equal the source voltage, approximately 12 VDC.
  6. Remove the iron or steel piece; the voltmeter should read 0 VDC.
  7. Connect the speed sensor leads and adjust the air gap.
Circuit Breaker Installation installation

⚠ Hazardous voltage. Operate the generator set only when all guards and electrical enclosures are in place.

  1. Place the generator set master switch in the OFF position.
  2. Disconnect the generator set engine starting battery, negative (--) lead first.
  3. Remove the six screws from the right side junction box panel and remove the panel.
  4. Install the circuit breaker on the new panel with the screws and washers, ON side toward the rear.
  5. Attach stator leads L1, L2, and L3 to the extension leads or line side of the circuit breaker.
  6. Connect the neutral stator leads to the L0 stud.
  7. Connect the load side of the circuit breaker to customer-supplied craft wiring and neutral to L0.
  8. Attach the new panel to the junction box using the original six screws.
  9. Check master switch is OFF and reconnect the starting battery, negative (--) lead last.
Electronic Governor Actuator Installation (John Deere) installation
  1. Install the new cover seal into the groove of the integrated actuator cover assembly.
  2. Position the integrated actuator cover assembly into the top of the pump while holding the metering valve drive coupling parallel to the pump body.
  3. Carefully slide the cover toward the rear of the pump body until the mounting holes align.
  4. Use two long cover screws and one short cover screw to assemble the cover to the pump body.
  5. Tighten the screws to 4--5 Nm (35--45 in. lb.).
  6. Install a new O-ring on the return line connector, coat lightly with all-purpose grease, and install; tighten to 5--6 Nm (43--55 in. lb.).
  7. Install the fuel return line to the return line connector.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
TB12PGEN (+)PGEN communication connection on TB12
TB13-SBNSpeed Bias Negative (--)
TB13-SBPSpeed Bias Positive (+)
TB13-VBNVoltage Bias Negative (--)
TB13-VBPVoltage Bias Positive (+)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What size generator is the Kohler 50EFOZD?

The Kohler 50EFOZD is rated 50 kW standby.

Is the Kohler 50EFOZD diesel or gas?

The Kohler 50EFOZD runs on diesel.

What is the coolant capacity of the Kohler 50EFOZD?

The Kohler 50EFOZD cooling system holds 14 liters (3.7 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

How much oil does the Kohler 50EFOZD take?

The Kohler 50EFOZD has an engine oil capacity of 14 liters (14.8 US quarts), per the manufacturer specification sheet.

How much does the Kohler 50EFOZD weigh?

The Kohler 50EFOZD has a dry weight of 1087 kg (2396 lb).

What voltage does the Kohler 50EFOZD produce?

The Kohler 50EFOZD is offered in 115/230 V, 110/190 V, 110/220 V, 220/380 V, 230/400 V, 240/416 V, 1 and 3-phase.

What battery does the Kohler 50EFOZD use?

The Kohler 50EFOZD uses 12- or 24-volt V each, 625 CCA, per the manufacturer specification sheet.

What alternator comes on the Kohler 50EFOZD?

The Kohler 50EFOZD uses a Fast-Response X alternator. Insulation class Class H.

What oil filter does the Kohler 50EFOZD use?

The Kohler 50EFOZD uses oil filter part number GM32809.

What fuel filter does the Kohler 50EFOZD use?

The Kohler 50EFOZD uses fuel filter part numbers GM48727, GM50263.

What air filter does the Kohler 50EFOZD use?

The Kohler 50EFOZD uses air filter part number 226915.

Parts

154model family
Part #DescriptionQtySystem
225428BELTBelt Amazon eBay $16.14
226915Air Filter ElementAir filter Amazon eBay $43.43
229125V-Belt (Seawater Pump)1Belt Amazon eBay $22.07 NAPA $17.52 FridayParts $62.70
229678Filter, oilOil filter Amazon eBay $24.45 PartsGeek $7.98 NAPA $9.09
229715Element, fuelFuel filter Amazon eBay $11.99 NAPA $16.83 KuduParts $11.00 FridayParts $13.52
229826Seawater Pump Impeller Kit1Impeller Amazon eBay $45.71 NAPA $40.56 FridayParts $33.59
229955IMPELLER REPAIR KIT6Impeller buy
239282BRUSH2Brush Amazon eBay $37.28
241481Switch, high temperature 268298 Sender, water temperature1Sensor Amazon eBay
249872Exhaust Temperature Switch (Isolated Ground Close, Open 102°C±15°C (215°F±5°F))Exhaust temperature switch Amazon eBay
249989BELT, SEAWATER PUMP1Belt Amazon eBay $19.76
252834Filter, oil1Oil filter Amazon eBay $27.95 PartsGeek $7.98 NAPA $9.09
256503BELT, SEAWATER PUMP1Belt Amazon eBay $18.44
264390Sender, oil pressure1Sensor Amazon eBay
267987FILTER, PRIMARY FUEL1Fuel filter Amazon eBay $14.99 KuduParts $18.00 FridayParts $19.99
268298Sender, water temperature1Sensor Amazon eBay
276148BELT1Belt Amazon eBay $35.00
322056-SFILTER, SECONDARY FUELFuel filter Amazon eBay $10.32
328309Switch assembly, pressure (oil pressure)1Sensor Amazon eBay $45.00
359771FILTER, OIL1Oil filter Amazon eBay $22.46 FridayParts $66.23
359978IMPELLER REPAIR KIT1Impeller FridayParts $66.23
359979SPARK PLUG2Spark plug Amazon eBay $18.27
363064BELTBelt Amazon eBay $40.07
363205BELT1Belt Amazon eBay $25.11
52 050 02-SFilter, oil1Oil filter Amazon
ED0021750010-SOIL FILTER1Oil filter Amazon eBay $109.95 FridayParts $19.50
ED0021752800-SOIL FILTER1Oil filter Amazon eBay $22.90 FridayParts $19.99
ED0021752850-SOil Filter1Oil filter Amazon eBay $24.95 NAPA $15.26
ED0021752880-SFuel Filter Element1Fuel filter Amazon eBay $49.95 KuduParts $14.00 FridayParts $16.25
ED0021753180-SSECONDARY FUEL FILTER1Fuel filter Amazon eBay $72.00 KuduParts $34.00 FridayParts $36.00
ED0021753200-SSECONDARY FUEL FILTER1Fuel filter Amazon eBay $17.99 NAPA $43.91 FridayParts $68.86
GM102586BELTBelt Amazon eBay $36.71
GM103820PRIMARY FUEL FILTERFuel filter buy
GM117329Seawater Pump Impeller KitImpeller Amazon eBay
GM13660V-BELTBelt Amazon eBay $23.18
GM15402BELT1Belt Amazon eBay $34.50
GM18704BELTBelt Amazon eBay
GM18793IMPELLER REPAIR KIT1Impeller Amazon eBay $49.95
GM18808FILTER, SECONDARY FUEL1Fuel filter Amazon eBay $20.00
GM18821FILTER, PRIMARY FUEL1Fuel filter Amazon eBay $49.99
GM20852IMPELLER REPAIR KITImpeller buy
GM28351Filter, oil1Oil filter Amazon eBay $19.46 NAPA $9.09
GM29290Oil Pressure Sender (Decision-Maker 550)Oil pressure sender Amazon eBay
GM30263Low Seawater Pressure SwitchLow seawater pressure switch Amazon eBay
GM31045-1Coolant Temperature Sender (Decision-Maker 550)1Coolant temperature sender Amazon eBay
GM32359Filter, fuel1Fuel filter Amazon eBay $26.87 NAPA $27.27 KuduParts $20.00
GM32809FILTER, OIL1Oil filter Amazon Amazon Amazon Amazon eBay $26.25 NAPA $28.76
GM34570FILTER, SECONDARY FUEL1Fuel filter Amazon eBay $34.05
GM35825BELT1Belt Amazon eBay $133.60
GM35826SPARK PLUG4Spark plug Amazon eBay $13.00 NAPA $2.64
GM39458Coolant Temperature Sender (Decision-Maker 3+)1Sensor Amazon eBay
GM40998BELTBelt Amazon eBay $45.65
GM40999FILTER, OILOil filter Amazon eBay $40.00
GM41014PRIMARY FUEL FILTERFuel filter Amazon eBay $70.50
GM46180SPARK PLUG2Spark plug Amazon eBay $15.14
GM47044BELTBelt Amazon eBay $33.24
GM47208Water Temperature Sender (Decision-Maker 550)Water temperature sender Amazon eBay
GM47465Filter, oil1Oil filter Amazon eBay $23.52 FridayParts $20.19
GM48727FILTER, PRIMARY FUEL1Fuel filter Amazon eBay $24.99
GM48728FILTER, SECONDARY FUEL1Fuel filter Amazon eBay $100.76
GM48729FILTER, PRIMARY FUEL1Fuel filter Amazon eBay $24.99
GM48730FILTER, SECONDARY FUEL1Fuel filter Amazon eBay $25.50
GM48731FILTER, OIL1Oil filter Amazon eBay $49.99 NAPA $3.59
GM49315FILTER, SECONDARY FUELFuel filter Amazon eBay $15.75
GM49316IMPELLER REPAIR KITImpeller buy
GM50200Oil FilterOil filter Amazon eBay
GM50263FILTER, PRIMARY FUEL (Includes primary and secondary filter elements)1Fuel filter Amazon eBay $99.99
GM50644IMPELLER REPAIR KIT1Impeller Amazon eBay $30.00
GM53040BELT, SEAWATER PUMPBelt Amazon eBay $19.94
GM77091BELT, SEAWATER PUMP1Belt buy
GM86446Air Filter ElementAir filter Amazon eBay $34.99 KuduParts $43.00
GM87479Air Filter ElementAir filter Amazon eBay
GM88686BELTBelt Amazon eBay $43.03
GM90310Air Filter ElementAir filter Amazon eBay
GM90645BELT, SEAWATER PUMP1Belt Amazon eBay $30.30
GM91974FUEL FILTER KITFuel filter Amazon eBay
GM98756IMPELLER REPAIR KITImpeller Amazon eBay
GM98801BELTBelt Amazon eBay
GM98860Air Filter ElementAir filter Amazon eBay
JW250000Circuit breaker mounting panelMounting panel Amazon eBay
RDO-26Loss of ECM Communication RDO-26*4ECM / ECU Amazon eBay
X-6348-6DECAL12Decals Amazon eBay
X-6348-9DECAL1Decals buy
223316Fuse, 10 A, 250 V1Service part / kit Amazon eBay $31.37
239298Fuse: Customer Connection (F3) 5 Amp1Service part / kit Amazon eBay $7.74 NAPA $2632.97
243273Fuse, 3 amp5Service part / kit Amazon eBay
25071910-AMP CIRCUIT BREAKERService part / kit eBay $39.88
2584058-AMP FUSE5Service part / kit Amazon eBay $15.60
260085ZINC ANODE KIT1Service part / kit Amazon eBay $16.99
262389FUSE, 25-AMP5Service part / kit Amazon eBay $14.83
267928ZINC ANODE KIT1Service part / kit buy
283645Fuse, 15 Amp5Service part / kit Amazon eBay
344835CONTAINER1Service part / kit eBay
352142ZINC ANODE KIT1Service part / kit Amazon eBay $26.09
358337Fuse: Auxiliary Winding (F1) 10 Amp1Service part / kit Amazon eBay $45.17 NAPA $65.06
ED0090802150-SZINC ANODE KIT1Service part / kit Amazon eBay $60.67
ED0090802840-SZINC ANODE KIT1Service part / kit Amazon eBay $92.76
GM105310KIT NUMBER (genuine parts kit)Service part / kit eBay
GM12310KIT NUMBERService part / kit buy
GM12314KIT NUMBER (genuine parts kit)Service part / kit eBay
GM20849FUSE, 10 AMPService part / kit buy
GM20851FUSE, 25 AMPService part / kit buy
GM20853ZINC ANODE KITService part / kit buy
GM24404KIT NUMBERService part / kit buy
GM32330KIT NUMBERService part / kit buy
GM32331KIT NUMBERService part / kit buy
GM32338KIT NUMBERService part / kit buy
GM39266Fuse: Controller, Fuel Pump, and Fuel Shutoff Solenoid (F2) 20 Amp5Service part / kit Amazon eBay $14.88
GM4233710-AMP FUSE5Service part / kit buy
GM4233925-AMP FUSE5Service part / kit buy
GM47427FUSE, 20-AMP5Service part / kit buy
GM48014BELT, SEAWATER PUMP1Service part / kit buy
GM48015KIT NUMBERService part / kit buy
GM51354KIT NUMBERService part / kit buy
GM51355KIT NUMBERService part / kit buy
GM51356KIT NUMBERService part / kit buy
GM51357KIT NUMBERService part / kit buy
GM51358KIT NUMBERService part / kit buy
GM84053KIT NUMBER (genuine parts kit)Service part / kit eBay
GM84054KIT NUMBER (genuine parts kit)Service part / kit eBay
GM89804Sea Spares® kitService part / kit buy
GM89805Sea Spares® kitService part / kit buy
GM95659KIT NUMBER (genuine parts kit)Service part / kit eBay
GM95660Sea Spares® kitService part / kit buy
GM99047Sea Spares® kitService part / kit buy
GV15402CIRCUIT BREAKER, 10-AMP1Service part / kit buy
GV42337FUSE, 10-AMP5Service part / kit buy
GV42339FUSE, 25-AMP5Service part / kit buy
RDO-01Overspeed Shutdown RDO-01 (lead 39)10Service part / kit Amazon eBay
RDO-03High Cool Temp Shutdown RDO-03 (lead 36)10Service part / kit Amazon eBay
RDO-04High Oil Temp Shutdown RDO-04 (lead 38)10Service part / kit Amazon eBay
RDO-05Low Coolant Temp Warning RDO-05 (lead 35)10Service part / kit Amazon eBay
RDO-06High Cool Temp Warning RDO-06 (lead 40)10Service part / kit Amazon eBay
RDO-07High Oil Temp Warning RDO-07 (lead 41)10Service part / kit Amazon eBay
RDO-08Low Fuel Warning RDO-08 (lead 63)9Service part / kit Amazon eBay
RDO-09Master Switch Error RDO-09 (lead 80)10Service part / kit Amazon eBay
RDO-10NFPA 110 Fault RDO-10 (lead 32)10Service part / kit Amazon eBay
RDO-12Low Battery Voltage RDO-12 (lead 62)10Service part / kit Amazon eBay
RDO-14Emergency Stop RDO-14 (lead 48)10Service part / kit Amazon eBay
RDO-15Generator Set Running RDO-15 (lead 70R)10Service part / kit Amazon eBay
RDO-16Time Delay Engine Cooldown (TDEC)1Service part / kit Amazon eBay
RDO-17System Ready1Service part / kit Amazon eBay
RDO-18Defined Common Fault10Service part / kit Amazon eBay
RDO-19Low Coolant Level Shutdown RDO-1910Service part / kit Amazon eBay
RDO-20Over Voltage Shutdown RDO-20 (lead 26)7Service part / kit Amazon eBay
RDO-22EPS Supplying Load RDO-2210Service part / kit Amazon eBay
RDO-23Fuel Valve Relay10Service part / kit Amazon eBay
RDO-24Reverse Power Shutdown1Service part / kit Amazon eBay
RDO-25Weak Battery Off Warning RDO-25Service part / kit Amazon eBay
RDO-27Underfrequency Shutdown1Service part / kit Amazon eBay
RDO-28Over Speed Shutdown RDO-287Service part / kit Amazon eBay
RDO-29Time Delay Engine Cooldown RDO-298Service part / kit Amazon eBay
RDO-30Load Shed KW Overload RDO-3010Service part / kit Amazon eBay
RDO-31Load Shed Underfrequency RDO-3110Service part / kit Amazon eBay

Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
Prime25%4.61.2
Prime50%7.62.0
Prime75%10.82.9
Prime100%14.13.7

Available documents

Spec sheet (Kohler)Spec sheet — g2160 (Kohler)Operator's manual — tp6861 (Kohler)Reference (Kohler)Reference — 2017-Marine-Product-Guide-g12480 (Kohler)Reference — Kohler-Pleasure-Craft-Marine-Generators (Kohler)Reference — Marine pocket guide (Kohler)Reference — PleasureCraft SpecificationSheet (Kohler)Reference — g12440 (Kohler)Parts manual (Kohler)Parts manual — 2017-Sea-Spares-Brochure-g12202 (Kohler)Parts manual — G12-202-11-20-Sea-Spares-Kits-brochure (Kohler)Service manual — tp6442 eng bg9k (Kohler)Service manual — tp6862-Installation-Manual-33-175EFOZDJ-EFOZCJ (Kohler)

This page was generated from the 14 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.

Full service, cheapest listings

Priced items from this model's own parts manual.

Air filter 226915$43.43
Fuel filter GM48727$24.99
Fuel filter (primary) GM50263$99.99
Oil filter GM32809$26.25
Belt GM15402$34.50
5 priced items$229.16