Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 350 kW |
| Standby kVA | 438 |
| Prime power | 320 kW |
| Emissions | Tier 3 |
| Oil capacity | 42.0 L |
| Alternator | Fast-Response PMG (Class Class H insulation) |
| Voltage options | 120/208 V, 127/220 V, 139/240 V, 220/380 V, 240/416 V, 277/480 V, 120/240 V, 347/600 V |
| Phase | 3 |
| Power factor | 0.8 |
| Battery cranking | 925 CCA |
| Battery voltage | 12 V |
| Battery quantity | 2 |
| Coolant capacity | 67.2 L |
| Engine jacket water | 18.0 L |
| Max ambient | 50 °C |
| Dimensions (L×W×H) | 3630×1725×1993 mm |
Engine
| Oil capacity | 42.0 L |
|---|---|
| Coolant capacity | 67.2 L |
| Displacement | 13.5 L |
| Aspiration | Turbocharged, Charge Air-Cooled |
| Rated speed | 1800 rpm |
Filters for the John Deere 6135HF485T
3Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.
| System | Filter | Description | Cross-references | |
|---|---|---|---|---|
| Oil filter | P550595 | Lube Filter, Spin-On Combination | JOHN DEERE DZ118269, JOHN DEERE RE530107, NAPA 7777, BALDWIN BD7310 | KuduParts $44.00 |
| Fuel filter | P502392 | Fuel Filter, Box | JOHN DEERE N378886, BALDWIN BF7912, SEPAR 01030, SEPAR 01030HV | FridayParts $39.99 |
| Fuel / water separator | P552952 | Fuel Filter, Water Separator Spin-On | JOHN DEERE DZ130550, JOHN DEERE RE532952, NAPA 3969, BALDWIN BF9866-O | FridayParts $59.99 |
Service specifications
30| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Other | 10 in. weld flange bolt circle diameter B | 361.95 | mm (14.25 in.) | |
| Other | 10 in. weld flange outside diameter C | 406.4 | mm (16.0 in.) | |
| Other | 10 in. weld flange quantity of bolts / bolt hole diameter D | 12, 25.40 | mm (1.00 in.) | |
| Other | 12 in. weld flange bolt circle diameter B | 431.80 | mm (17.00 in.) | |
| Other | 12 in. weld flange outside diameter C | 482.6 | mm (19.0 in.) | |
| Other | 12 in. weld flange quantity of bolts / bolt hole diameter D | 12, 25.40 | mm (1.00 in.) | |
| Other | 14 in. weld flange bolt circle diameter B | 476.25 | mm (18.75 in.) | |
| Other | 14 in. weld flange outside diameter C | 533.4 | mm (21.0 in.) | |
| Other | 14 in. weld flange quantity of bolts / bolt hole diameter D | 12, 28.58 | mm (1.13 in.) | |
| Other | 16 in. weld flange bolt circle diameter B | 539.75 | mm (21.25 in.) | |
| Other | 16 in. weld flange outside diameter C | 596.9 | mm (23.5 in.) | |
| Other | 16 in. weld flange quantity of bolts / bolt hole diameter D | 16, 28.58 | mm (1.13 in.) | |
| Other | 18 in. weld flange bolt circle diameter B | 577.85 | mm (22.75 in.) | |
| Other | 18 in. weld flange outside diameter C | 635.0 | mm (25.0 in.) | |
| Other | 18 in. weld flange quantity of bolts / bolt hole diameter D | 16, 31.75 | mm (1.25 in.) | |
| Other | 20 in. weld flange bolt circle diameter B | 635.00 | mm (25.00 in.) | |
| Other | 20 in. weld flange outside diameter C | 698.5 | mm (27.5 in.) | |
| Other | 20 in. weld flange quantity of bolts / bolt hole diameter D | 20, 31.75 | mm (1.25 in.) | |
| Other | 5 in. weld flange bolt circle diameter B | 215.90 | mm (8.50 in.) | |
| Other | 5 in. weld flange outside diameter C | 241.30 | mm (9.50 in.) | |
| Other | 5 in. weld flange quantity of bolts / bolt hole diameter D | 8, 22.23 | mm (0.88 in.) | |
| Other | 6 in. weld flange bolt circle diameter B | 254.0 | mm (10.0 in.) | |
| Other | 6 in. weld flange outside diameter C | 279.4 | mm (11.0 in.) | |
| Other | 6 in. weld flange quantity of bolts / bolt hole diameter D | 8, 22.23 | mm (0.88 in.) | |
| Other | 8 in. weld flange bolt circle diameter B | 298.45 | mm (11.75 in.) | |
| Other | 8 in. weld flange outside diameter C | 342.9 | mm (13.5 in.) | |
| Other | 8 in. weld flange quantity of bolts / bolt hole diameter D | 8, 22.23 | mm (0.88 in.) | |
| Other | Weld flange angle A (10, 12, 14 in. nominal pipe size) | 30 | deg. | |
| Other | Weld flange angle A (16, 18, 20 in. nominal pipe size) | 22.5 | deg. | |
| Other | Weld flange angle A (5, 6, 8 in. nominal pipe size) | 45 | deg. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Voltage reconnection
| Voltage | Phase | Connection | Leads | Notes |
|---|---|---|---|---|
| 12-lead optional voltage connections | 12 | Alternator optional feature | ||
| 4-lead dedicated voltages | 4 | Alternator standard feature | ||
| 110/127/139/240/254/277 | single-phase | switchable | Towable generator model specifications; some models n/a | |
| 208/220/240/415/440/480 | 3-phase | reconnectable | Towable generator model specifications | |
| 208/220/240/415/440/480 | 3-phase | switchable | Towable generator model specifications |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Common questions
What size generator is the Kohler 350REOZJ?
The Kohler 350REOZJ is rated 350 kW standby (438.0 kVA).
What engine is in the Kohler 350REOZJ?
The Kohler 350REOZJ is powered by the John Deere 6135HF485T engine.
Is the Kohler 350REOZJ diesel or gas?
The Kohler 350REOZJ runs on Diesel.
What's the oil capacity on a Kohler 350REOZJ?
The John Deere 6135HF485T engine in the Kohler 350REOZJ has an oil capacity of 42.0 liters.
How much coolant does the Kohler 350REOZJ hold?
The Kohler 350REOZJ cooling system holds 67.2 liters (17.8 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the prime power rating of the Kohler 350REOZJ?
The Kohler 350REOZJ is rated 320 kW prime (400 kVA), against 350 kW standby.
What voltages is the Kohler 350REOZJ available in?
The Kohler 350REOZJ is offered in 120/208 V, 127/220 V, 139/240 V, 220/380 V, 240/416 V, 277/480 V, 3-phase.
How many cold cranking amps does the Kohler 350REOZJ require?
The Kohler 350REOZJ uses 2 batteryies, 12 V each, 925 CCA, per the manufacturer specification sheet.
Which alternator is fitted to the Kohler 350REOZJ?
The Kohler 350REOZJ uses a Fast-Response PMG alternator. Insulation class Class H.
Parts
6model family| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 300REZXD | 300 KW L.P./N.G. GENSET | 1 | Service part / kit | Amazon eBay |
| 350EOZCS | 350 KW DIESEL COMMERCIAL MARINE GENSET | 1 | Service part / kit | Amazon eBay |
| 350REZXD | 350 KW L.P./N.G. GENSET | 1 | Service part / kit | Amazon eBay |
| 400REOZJC | 400 KW DIESEL GENSET | 1 | Service part / kit | Amazon eBay $1799.95 |
| 500REOZJC | 500 KW DIESEL GENSET | 1 | Service part / kit | Amazon eBay $1799.95 |
| KG80R | 80 kW L.P./N.G. Genset | 1 | Service part / kit | Amazon eBay |
Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 25% | 27.2 | 7.2 |
| Prime | 50% | 47.6 | 12.6 |
| Prime | 75% | 66.1 | 17.5 |
| Prime | 100% | 88.3 | 23.3 |
| Standby | 25% | 30.7 | 8.1 |
| Standby | 50% | 51.9 | 13.7 |
| Standby | 75% | 73.2 | 19.3 |
| Standby | 100% | 100.3 | 26.5 |
Available documents
This page was generated from the 8 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.