Specifications
| Fuel | diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 355 kW |
| Standby kVA | 420 |
| Prime power | 320 kW |
| Emissions | EPA Tier 3 |
| Controller | DSE7310 |
| Oil capacity | 50.0 L |
| Alternator | Stamford/AvK HCI444E |
| Voltage options | 120/208 V |
| Phase | 3 |
| Rated current | 1231.73 A |
| Power factor | 0.8 |
| Circuit breaker | 1110 A |
| Battery group | Not specified |
| Battery voltage | 12 V |
| Battery quantity | 1 |
| Coolant capacity | 32.5 L |
| Max ambient | Not specified °C |
| Sound level | 77.0 dBA @ 7 m |
| Tank runtime | Not specified hr |
Engine
| Oil capacity | 50.0 L |
|---|---|
| Displacement | 13.5 L |
| Aspiration | TURBOCHARGED |
| Rated speed | 1800 rpm |
Filters for the John Deere 6135HF485 - 401
3Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.
| System | Filter | Description | Cross-references | |
|---|---|---|---|---|
| Oil filter | P550595 | Lube Filter, Spin-On Combination | JOHN DEERE DZ118269, JOHN DEERE RE530107, NAPA 7777, BALDWIN BD7310 | KuduParts $44.00 |
| Fuel filter | P502392 | Fuel Filter, Box | JOHN DEERE N378886, BALDWIN BF7912, SEPAR 01030, SEPAR 01030HV | FridayParts $39.99 |
| Fuel / water separator | P552952 | Fuel Filter, Water Separator Spin-On | JOHN DEERE DZ130550, JOHN DEERE RE532952, NAPA 3969, BALDWIN BF9866-O | FridayParts $59.99 |
Common questions
How many kW is the Hipower HJW 355 T6?
The Hipower HJW 355 T6 is rated 355 kW standby (420.0 kVA).
Which engine powers the Hipower HJW 355 T6?
The Hipower HJW 355 T6 is powered by the John Deere 6135HF485 - 401 engine.
Is the Hipower HJW 355 T6 diesel or gas?
The Hipower HJW 355 T6 runs on diesel.
What's the oil capacity on a Hipower HJW 355 T6?
The John Deere 6135HF485 - 401 engine in the Hipower HJW 355 T6 has an oil capacity of 50.0 liters.
What is the coolant capacity of the Hipower HJW 355 T6?
The Hipower HJW 355 T6 cooling system holds 32.5 liters (8.6 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the continuous rating of the Hipower HJW 355 T6?
The Hipower HJW 355 T6 is rated 320 kW prime (400 kVA), against 355 kW standby.
How loud is the Hipower HJW 355 T6?
The Hipower HJW 355 T6 is rated at 77.0 dBA at 7 m, per the manufacturer specification sheet.
What voltages is the Hipower HJW 355 T6 available in?
The Hipower HJW 355 T6 is offered in 120/208 V, 3-phase.
What battery does the Hipower HJW 355 T6 use?
The Hipower HJW 355 T6 uses 1 battery, 12 V each, group Not specified, per the manufacturer specification sheet.
What alternator comes on the Hipower HJW 355 T6?
The Hipower HJW 355 T6 uses a Stamford/AvK HCI444E alternator.
Available documents