Specifications
| Fuel | Natural Gas |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 750 kW |
| Standby kVA | 938 |
| Prime power | 675 kW |
| Emissions | EPA Certified |
| Controller | Power Zone, PowerZone Pro Sync |
| Oil capacity | 160.0 L |
| Alternator | K0912124Y22 |
| Voltage options | 120/208 V, 120/240 V, 277/480 V, 346/600 V |
| Phase | Three-Phase |
| Rated current | 2,605 A |
| Power factor | 0.8 |
| Circuit breaker | 2,605 A |
| Battery group | 4 |
| Battery cranking | See Battery Index 0161970SBY CCA |
| Battery voltage | 12 VDC V |
| Battery quantity | 4 |
| Coolant capacity | 55.0 L |
| Max ambient | 50 °C |
| Dimensions (L×W×H) | 4637×2141×3606 mm |
| Dry weight | 7426 kg |
| Fuel tank | 199270.0 L |
| Tank runtime | See Bulletin No. 0199270SSD hr |
Engine
| Oil capacity | 160.0 L |
|---|---|
| Coolant capacity | 55.0 L |
| Displacement | 33.9 L |
| Aspiration | Turbocharged/Aftercooled |
| Rated speed | 1 rpm |
Common questions
What size generator is the Generac SG750?
The Generac SG750 is rated 750 kW standby (938.0 kVA).
Which engine powers the Generac SG750?
The Generac SG750 is powered by the Generac SG750 engine.
What fuel does the Generac SG750 use?
The Generac SG750 runs on Natural Gas.
What's the oil capacity on a Generac SG750?
The Generac SG750 engine in the Generac SG750 has an oil capacity of 160.0 liters.
What is the coolant capacity of the Generac SG750?
The Generac SG750 cooling system holds 55 liters (14.5 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the continuous rating of the Generac SG750?
The Generac SG750 is rated 675 kW prime (844 kVA), against 750 kW standby.
What is the dry weight of the Generac SG750?
The Generac SG750 has a dry weight of 7426 kg (16371 lb).
What size fuel tank does the Generac SG750 have?
The Generac SG750 has a 199270 liter (52642 US gallon) fuel tank, giving about See Bulletin No. 0199270SSD hours of runtime.
What voltages is the Generac SG750 available in?
The Generac SG750 is offered in 120/208 V, 120/240 V, 277/480 V, 346/600 V, Three-Phase-phase.
What size battery does the Generac SG750 need?
The Generac SG750 uses 4 batteryies, 12 VDC V each, See Battery Index 0161970SBY CCA, group 4, per the manufacturer specification sheet.
What alternator does the Generac SG750 use?
The Generac SG750 uses a K0912124Y22 alternator.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Standby | 25% | 2.0 | 77.0 |
| Standby | 50% | 4.0 | 116.0 |
| Standby | 75% | 5.0 | 165.0 |
| Standby | 100% | 7.0 | 220.0 |
Available documents