Service parts for the SG275
Grouped by system, with how many of each the parts manual calls for.
Oil system
1 requiredPrices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.
Specifications
| Fuel | Natural Gas |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 275 kW |
| Standby kVA | 344 |
| Prime power | 248 kW |
| Emissions | EPA Certified |
| Controller | Digital H Control Panel - Dual 4x20 Display |
| Oil capacity | 34.3 L |
| Alternator | 520 |
| Voltage options | 120/208 V, 120/240 V, 277/480 V, 346/600 V |
| Phase | Three-Phase |
| Rated current | 955 A |
| Power factor | 0.8 |
| Battery group | 2 |
| Battery cranking | 1000 CCA |
| Battery voltage | 12 V |
| Battery quantity | 12 |
| Coolant capacity | 71.9 L |
| Max ambient | 50 °C |
| Dimensions (L×W×H) | 3524×1463×1728 mm |
| Dry weight | 2998 kg |
| Sound level | 90.0 dBA @ 23 m |
| Fuel tank | 0.0 L |
| Tank runtime | 0 hr |
Engine
| Oil capacity | 34.3 L |
|---|---|
| Coolant capacity | 71.9 L |
| Displacement | 12.88 L |
| Aspiration | Turbocharged/Aftercooled |
| Rated speed | 2150 rpm |
Maintenance & consumables
for the Generac SG275| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | Air Cleaner | — | |||
| Fuel filter | Fuel Type | — | |||
| Oil filter | Oil Filter Type | — | |||
| Battery | Battery Size | — | |||
| Belt | Fan Type | — | |||
| Oil | Crankcase Capacity | 34.3 L | 0161970SBY | Amazon eBay | |
| Spark plug | Ignition | — |
Common questions
What size generator is the Generac SG275?
The Generac SG275 is rated 275 kW standby (344.0 kVA).
Which engine powers the Generac SG275?
The Generac SG275 is powered by the Generac SG275 engine.
What fuel does the Generac SG275 use?
The Generac SG275 runs on Natural Gas.
What's the oil capacity on a Generac SG275?
The Generac SG275 engine in the Generac SG275 has an oil capacity of 34.3 liters.
What is the coolant capacity of the Generac SG275?
The Generac SG275 cooling system holds 71.9 liters (19.0 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the prime power rating of the Generac SG275?
The Generac SG275 is rated 248 kW prime (309 kVA), against 275 kW standby.
How loud is the Generac SG275?
The Generac SG275 is rated at 90.0 dBA at 23 m, per the manufacturer specification sheet.
What is the dry weight of the Generac SG275?
The Generac SG275 has a dry weight of 2998 kg (6609 lb).
What voltages is the Generac SG275 available in?
The Generac SG275 is offered in 120/208 V, 120/240 V, 277/480 V, 346/600 V, Three-Phase-phase.
What size battery does the Generac SG275 need?
The Generac SG275 uses 12 batteryies, 12 V each, 1000 CCA, group 2, per the manufacturer specification sheet.
What alternator comes on the Generac SG275?
The Generac SG275 uses a 520 alternator.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Standby | 25% | 189.27 | 50.0 |
| Standby | 50% | 276.34 | 73.0 |
| Standby | 75% | 348.26 | 92.0 |
| Standby | 100% | 442.89 | 117.0 |
Available documents
This page was generated from the 3 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.