Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 200 kW |
| Standby kVA | 280 |
| Prime power | 180 kW |
| Emissions | Tier III |
| Controller | Digital H Control Panel - Dual 4x20 Display |
| Oil capacity | 28.0 L |
| Alternator | Upsize 2 (6-pole, Class H insulation) |
| Voltage options | 120/240 V, 120/208 V, 277/480 V, 346/600 V |
| Phase | Three-Phase |
| Rated current | 833 A |
| Power factor | 0.8 |
| Circuit breaker | 2000 A |
| Battery group | 2 |
| Battery cranking | 1000 CCA |
| Battery voltage | 24VDC V |
| Battery quantity | 2 |
| Coolant capacity | 28.0 L |
| Max ambient | 104 °C |
| Dimensions (L×W×H) | 154×53×68 mm |
| Dry weight | 6316 kg |
| Fuel tank | 128.0 L |
| Tank runtime | 10 hr |
Engine
| Oil capacity | 28.0 L |
|---|---|
| Coolant capacity | 12.7 L |
| Displacement | 8.7 L |
| Aspiration | Turbocharged/Aftercooled |
| Rated speed | 1800 rpm |
Maintenance & consumables
for the Iveco/FPT SD200| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | Direct, Flexible Disc | — | |||
| Fuel filter | Primary fuel filter | — | |||
| Oil filter | Full-Flow | — | |||
| Battery | 24VDC | ×2 | — | ||
| Belt | Stainless steel flexible exhaust connection | — | |||
| Oil | 28 | 28.0 L | — | ||
| Spark plug | N/A | — |
Common questions
What is the power rating of the Generac SD200?
The Generac SD200 is rated 200 kW standby (280.0 kVA).
Which engine powers the Generac SD200?
The Generac SD200 is powered by the Iveco/FPT SD200 engine.
What fuel does the Generac SD200 use?
The Generac SD200 runs on Diesel.
What is the oil capacity of the Generac SD200?
The Iveco/FPT SD200 engine in the Generac SD200 has an oil capacity of 28.0 liters.
How much coolant does the Generac SD200 hold?
The Generac SD200 cooling system holds 28 liters (7.4 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the prime power rating of the Generac SD200?
The Generac SD200 is rated 180 kW prime (250 kVA), against 200 kW standby.
What is the dry weight of the Generac SD200?
The Generac SD200 has a dry weight of 6316 kg (13924 lb).
What size fuel tank does the Generac SD200 have?
The Generac SD200 has a 128 liter (34 US gallon) fuel tank, giving about 10 hours of runtime.
What voltages is the Generac SD200 available in?
The Generac SD200 is offered in 120/240 V, 120/208 V, 277/480 V, 346/600 V, Three-Phase-phase.
How many cold cranking amps does the Generac SD200 require?
The Generac SD200 uses 2 batteryies, 24VDC V each, 1000 CCA, group 2, per the manufacturer specification sheet.
Which alternator is fitted to the Generac SD200?
The Generac SD200 uses a Upsize 2 alternator. It has 6 poles. Insulation class H.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 25% | 12.1 | 2.6 |
| Prime | 50% | 24.6 | 5.2 |
| Prime | 75% | 37.1 | 7.9 |
| Prime | 80% | 15.1 | 4.0 |
| Prime | 100% | 50.0 | 10.5 |
| Standby | 25% | 14.8 | 3.9 |
| Standby | 50% | 29.9 | 7.9 |
| Standby | 70% | 16.7 | 4.4 |
| Standby | 75% | 45.4 | 12.0 |
| Standby | 100% | 61.3 | 16.2 |
Available documents
This page was generated from the 5 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.