| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 100 kW |
| Standby kVA | 125 |
| Prime power | 90 kW |
| Emissions | EPA Certified Stationary Emergency |
| Controller | Power Zone 410 |
| Oil capacity | 17.0 L |
| Alternator | K0100124Y21 Standard Model (4-pole, Class H insulation) |
| Voltage options | 120/240 V, 277/480 V, 346/600 V |
| Phase | 3-Phase |
| Rated current | 417 A |
| Power factor | 0.8 |
| Circuit breaker | 417 A |
| Battery group | See Battery Index 0161970SBY |
| Battery voltage | 12 V |
| Battery quantity | 1 |
| Coolant capacity | 21.4 L |
| Max ambient | See Bulletin No. 0199280SSD °C |
| Dimensions (L×W×H) | 2794×1016×1651 mm |
| Dry weight | 1408 kg |
| Fuel tank | 199280.0 L |
| Tank runtime | See Bulletin No. 0199280SSD hr |
Engine
| Oil capacity | 17.0 L |
|---|---|
| Coolant capacity | 21.4 L |
| Displacement | 6.7 L |
| Aspiration | Turbocharged/Aftercooled |
| Rated speed | 1800 rpm |
Maintenance & consumables
for the Iveco/FPT 6.7L| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | Cab fresh air filter | — | 50 hr | ||
| Fuel filter | 5 Micron | — | 600 hr | ||
| Oil filter | Full flow, Cartridge | — | 600 hr | ||
| Battery | 12 Volt, 90 A.H., 27F | — | |||
| Belt | — | ||||
| Coolant | Engine cooling system | — | 4000 hr | ||
| Coolant filter | 5 | — | |||
| Oil | Gear | 11.0 L | — | 600 hr | |
| Spark plug | 5 | — |
Common questions
What size generator is the Generac SD100?
The Generac SD100 is rated 100 kW standby (125.0 kVA).
Which engine powers the Generac SD100?
The Generac SD100 is powered by the Iveco/FPT 6.7L engine.
What kind of fuel does the Generac SD100 run on?
The Generac SD100 runs on Diesel.
What is the oil capacity of the Generac SD100?
The Iveco/FPT 6.7L engine in the Generac SD100 has an oil capacity of 17.0 liters.
What alternator comes on the Generac SD100?
The Generac SD100 uses a K0100124Y21 Standard Model alternator. It has 4 poles. Insulation class H.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Standby | 25% | 8.3 | 2.2 |
| Standby | 50% | 15.9 | 4.2 |
| Standby | 75% | 22.33 | 5.9 |