Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 40 kW |
| Standby kVA | 50 |
| Prime power | 36 kW |
| Emissions | EPA Certified Stationary Emergency |
| Controller | Digital H Control Panel- Dual 4x20 Display |
| Oil capacity | 7.0 L |
| Alternator | 390 mm (4-pole, Class H insulation) |
| Voltage options | 208/240 V, 208/208 V, 277/480 V, 346/600 V |
| Phase | Three-Phase |
| Rated current | 167 A |
| Power factor | 0.8 |
| Circuit breaker | 167 A |
| Battery group | See Battery Index 0161970SBY |
| Battery voltage | 12 V |
| Battery quantity | 1 |
| Coolant capacity | 9.5 L |
| Max ambient | 50 °C |
| Dimensions (L×W×H) | 1948×950×1147 mm |
| Dry weight | 790 kg |
| Sound level | 75.0 dBA @ 1 m |
| Fuel tank | 211.0 L |
| Tank runtime | 60 hr |
Engine
| Oil capacity | 7.0 L |
|---|---|
| Coolant capacity | 9.5 L |
| Displacement | 3.4 L |
| Aspiration | Turbocharged/Aftercooled |
| Rated speed | 1800 rpm |
Common questions
How many kW is the Generac SD040?
The Generac SD040 is rated 40 kW standby (50.0 kVA).
What engine does the Generac SD040 use?
The Generac SD040 is powered by the Generac SD040 engine.
What kind of fuel does the Generac SD040 run on?
The Generac SD040 runs on Diesel.
How much oil does the Generac SD040 take?
The Generac SD040 engine in the Generac SD040 has an oil capacity of 7.0 liters.
What is the coolant capacity of the Generac SD040?
The Generac SD040 cooling system holds 9.5 liters (2.5 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the prime power rating of the Generac SD040?
The Generac SD040 is rated 36 kW prime (45 kVA), against 40 kW standby.
What is the sound level of the Generac SD040?
The Generac SD040 is rated at 75.0 dBA at 1 m, per the manufacturer specification sheet.
What is the dry weight of the Generac SD040?
The Generac SD040 has a dry weight of 790 kg (1741 lb).
How big is the fuel tank on the Generac SD040?
The Generac SD040 has a 211 liter (56 US gallon) fuel tank, giving about 60 hours of runtime.
What voltages is the Generac SD040 available in?
The Generac SD040 is offered in 208/240 V, 208/208 V, 277/480 V, 346/600 V, Three-Phase-phase.
What size battery does the Generac SD040 need?
The Generac SD040 uses 1 battery, 12 V each, group See Battery Index 0161970SBY, per the manufacturer specification sheet.
What alternator does the Generac SD040 use?
The Generac SD040 uses a 390 mm alternator. It has 4 poles. Insulation class H.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Standby | 25% | 4.2 | 1.1 |
| Standby | 50% | 7.3 | 1.9 |
| Standby | 75% | 10.2 | 2.7 |
| Standby | 100% | 13.3 | 3.5 |
Available documents