Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 25 kW |
| Standby kVA | 32 |
| Prime power | 23 kW |
| Emissions | EPA Certified |
| Controller | H100 Digital |
| Oil capacity | 5.7 L |
| Alternator | K0025124Y21 A0025044N21 (4-pole, Class H insulation) |
| Voltage options | 120/240 V, 120/208 V, 277/480 V, 346/600 V |
| Phase | Single-Phase |
| Rated current | 104 A |
| Power factor | 0.8 |
| Circuit breaker | 104 A |
| Battery group | See Battery Index 0161970SBY |
| Battery voltage | 12 VDC V |
| Battery quantity | 1 |
| Coolant capacity | 9.5 L |
| Max ambient | 50 °C |
| Dimensions (L×W×H) | 1930×950×1138 mm |
| Dry weight | 661 kg |
| Tank runtime | N/A hr |
Engine
| Oil capacity | 10.6 L |
|---|---|
| Coolant capacity | 9.5 L |
| Displacement | 2.22 L |
| Aspiration | Turbocharged |
| Rated speed | 1800 rpm |
Common questions
How many kW is the Generac SD025?
The Generac SD025 is rated 25 kW standby (32.0 kVA).
What engine does the Generac SD025 use?
The Generac SD025 is powered by the Perkins SD025 engine.
What fuel does the Generac SD025 use?
The Generac SD025 runs on Diesel.
What is the oil capacity of the Generac SD025?
The Perkins SD025 engine in the Generac SD025 has an oil capacity of 10.6 liters.
What alternator comes on the Generac SD025?
The Generac SD025 uses a K0025124Y21 A0025044N21 alternator. It has 4 poles. Insulation class H.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Standby | 25% | 1.0 | 3.0 |
| Standby | 50% | 3.2 | 1.2 |
| Standby | 75% | 6.1 | 1.6 |
| Standby | 100% | 7.9 | 2.1 |