HomeGeneracGenerac Number

Generac Number Generator Set

The Generac Number is a 20 kW diesel standby generator set. It is available at 240 V, 3-phase.

20 kW
Standby
3
Document types

How to read your Generac serial & model number →

Typical fuel consumption for 20–25 kW Diesel generators →

Compare with other 20–25 kW Diesel generators →

Service parts for the Number

Grouped by system, with how many of each the parts manual calls for.

Air intake

1 required

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

Fueldiesel
Standby power20 kW
Voltage options240 V
Phase3-phase

Filters & service parts

model family
ItemSpecCapacityPart #Interval
Air filter140-1347150 hr Amazon eBay $100.60
Fuel filter
Oil filter150 hr
BatteryGroup 27 recommended (600 CCA min); Group 31 maximum (750 CCA min); 12 V
Belt1000 hr
CoolantGenerac brand 50/50 ethylene glycol type coolant11.0 L1000 hr
OilGenerac 5W-20 Synthetic (after 25 hour break-in); factory filled with 5W-20 conventional11.0 L150 hr
Spark plug300 hr

Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.

Service intervals

13
ItemActionHoursMonthsNotes
Accessory drive beltInspect1000 hr24 moSchedule C: inspect for wear or damage
Accessory drive beltReplace1000 hrSchedule C
Air filter elementReplace1000 hr24 moSchedule C
Coolant level and hosesInspect1000 hr24 moSchedule C
Coolant systemDrain1000 hr24 moSchedule C: drain/flush
Critical fastenersAdjust1000 hrSchedule C: tighten
Enclosure slots and openingsInspect1000 hr24 moSchedule C
Fuel hosesInspect1000 hr24 moSchedule C
Lubricating oil and oil filterReplace1000 hr24 moFirst service — Schedule C
Lubricating oil level and drain hoseInspect1000 hr24 moSchedule C
Radiator for cloggingInspect1000 hr24 moSchedule C
Spark plugsReplace1000 hr24 moSchedule C
BatteryReplace36 moReplace battery every three years; every two years in extreme conditions

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

2
TypeItemValueUnitCondition
GapSpark plug gap0.012-0.017in (0.31-0.45 mm)
TorqueSpark plug28ft-lb (38 Nm)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Coolant50/50 ethylene glycol11.0 LUse only Generac brand 50/50 ethylene glycol type coolant. Do not use propylene glycol. Mix ratio 40-60% antifreeze depending on ambient.
Engine oil5W-20SAE11.0 LFactory filled with 5W-20 conventional; after 25 hour break-in use Generac proprietary 5W-20 Synthetic. Once synthetic is used, use for life. Do not use special additives.
FuelLiquid Propane (LP) Vapor or Natural Gas (NG)LP energy density >= 91,420 BTU/US gal (25.5 MJ/L); NG >= 1,036 BTU/ft3 (37.3 MJ/m3)LP minimum tank size 250 US gal (946 L) recommended.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

10
Installing the Battery installation

⚠ Explosion. Batteries emit explosive gases. Always connect positive battery cable first to avoid spark. Failure to do so could result in death or serious injury. (W000133)

  1. Loosen nylon strap on battery tray.
  2. Install battery onto tray.
  3. Secure nylon strap over top of battery and tighten.
  4. Install positive battery cable (red) to positive terminal.
  5. Install negative battery cable (black) to negative terminal.
Cleaning/Gaping/Replacing Spark Plugs maintenance

⚠ Electric shock. Do not disconnect spark plug wires with engine running. Doing so could result in death or serious injury. (W000140)

Tools: spark plug socket, wire feeler gauge, wire brush

  1. Remove negative battery cable.
  2. Remove spark plug cables from terminals.
  3. Clean area around spark plugs.
  4. Remove spark plugs with spark plug socket.
  5. Inspect threads; clean with thread chaser if needed.
  6. Clean spark plugs with wire brush and solvent; do not blast.
  7. Inspect gap with wire feeler gauge; gap 0.012-0.017 in (0.31-0.45 mm).
  8. Adjust gap by bending ground electrode.
  9. Finger tighten spark plugs; tighten to 28 ft-lb (38 Nm) with socket.
  10. Install spark plug cables; verify captured in clips.
Draining and Flushing Coolant System maintenance

⚠ Risk of burns. Allow engine to cool before draining oil or coolant. Failure to do so could result in death or serious injury. (W000139)

Tools: wrenches, container, funnel

  1. Disconnect and empty coolant overflow reservoir.
  2. Rotate and remove plastic cover at top of enclosure.
  3. Slowly unscrew radiator cap.
  4. Locate drain screw at bottom left of radiator; open drain.
  5. Remove coolant drain hose from clamp; remove plug; drain coolant.
  6. Install drain plug and hose; close radiator drain screw.
  7. Fill radiator with de-ionized or distilled water and flushing product; use 2.9 US gal (11 L).
  8. Install radiator cap.
  9. Press MANUAL to start engine; run until thermostat opens.
  10. Inspect hoses for leaks; press OFF; allow engine to cool.
  11. Repeat steps 4-19 to drain.
  12. Add recommended coolant; top off radiator and overflow bottle.
Inspecting Accessory/Drive Belt maintenance
  1. Inspect belt for cracks, fraying, excessive wear, or damage.
  2. Verify belt is free of grease and oil.
  3. Replace belt if contaminated, damaged, frayed, or worn.
  4. Inspect belt and rotating components.
Preparing For Storage maintenance

Tools: wrenches, container

  1. Open viewing window.
  2. Press MANUAL to start engine; blue LED illuminates.
  3. Allow engine to reach normal operating temperature.
  4. Press OFF; red LED illuminates.
  5. Set generator MLCB to OFF (OPEN), if equipped.
  6. Remove 7.5 amp fuse.
  7. Turn off utility power to transfer switch.
  8. Place DO NOT OPERATE tag.
  9. Wait five minutes for engine to cool.
  10. Remove front access panel.
  11. Remove oil drain hose from holding clamp; drain oil.
  12. Install oil drain plug and hose.
  13. Remove oil filter; coat new filter gasket with oil.
  14. Install oil filter; tighten 3/4 to 1 full turn.
  15. Fill engine with recommended oil; install oil fill cap.
Removing Battery maintenance

⚠ Electrical shock. Disconnect battery ground terminal before working on battery or battery wires. Failure to do so could result in death or serious injury. (W000164)

  1. Remove negative battery cable from negative terminal.
  2. Remove positive battery cable from positive terminal.
  3. Install rubber protective cover over positive terminal.
  4. Release buckle on nylon strap securing battery.
  5. Grasp battery strap and lift battery from tray.
  6. Remove rubber protective cover from positive terminal.
Replacing Air Filter Element maintenance

Tools: wrenches

  1. Remove nut and bolt from air filter clamp; loosen elbow clamp.
  2. Remove air filter element and discard.
  3. Clean elbow of dust, dirt, or debris.
  4. Place new air filter element into elbow clamp.
  5. Install elbow clamp and tighten; install nut and bolt; tighten until snug.
Replacing Lubricating Oil and Oil Filter maintenance

⚠ Risk of burns. Allow engine to cool before draining oil or coolant. Failure to do so could result in death or serious injury. (W000139)

Tools: wrenches, container, shop towel

  1. Follow Removing From Service; wait at least 10 minutes.
  2. Remove oil drain hose from holding clamp.
  3. Use two wrenches to remove oil drain plug; drain oil.
  4. Install oil drain plug and hose into holding clamp.
  5. Turn oil filter counterclockwise to remove; wipe adapter.
  6. Apply clean engine oil to gasket of new oil filter.
  7. Install oil filter by hand until gasket contacts; tighten 3/4 to 1 full turn.
  8. Fill engine with 11.6 qt (11 L) recommended oil for 4.5 L NA.
  9. Install oil fill cap.
  10. Connect negative battery cable; install 7.5 amp fuse.
  11. Press MANUAL to start; run one minute; inspect for leaks.
  12. Press OFF; wait 10 minutes; check oil level and add as needed.
Return To Service maintenance
  1. Install 7.5 amp fuse.
  2. Install T1 fuse in transfer switch.
  3. Verify both emergency shutdown switches are ON.
  4. Press AUTO on controller; green LED illuminates.
  5. Set generator MLCB to ON (CLOSED), if equipped.
  6. Close viewing window.
  7. Remove DO NOT OPERATE tag from control panel and transfer switch.
  8. Reset date/time.
Starting and Running Engine operation

⚠ Automatic start-up. Disconnect utility power and render unit inoperable before working on unit. Failure to do so will result in death or serious injury. (D000191)

  1. Pull up rubber flap covering fuse holder; verify 7.5 amp fuse.
  2. Set generator MLCB to OFF (OPEN), if equipped.
  3. Verify both emergency shutdown switches are ON (I).
  4. Press MANUAL on controller to start engine; blue LED illuminates.
  5. Allow engine to reach normal operating temperature.
  6. Press OFF on controller to stop engine; red LED illuminates.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What is the power rating of the Generac Number?

The Generac Number is rated 20 kW standby.

Is the Generac Number diesel or gas?

The Generac Number runs on diesel.

What air filter does the Generac Number use?

The Generac Number uses air filter part number 140-1347.

Troubleshooting

6

Fault codes

CodeMeaningRemedy
7 kWEngine will not crank.Replace 15A fuse in generator control panel.
8 kWEngine cranks but will not start.Tighten, clean or replace as necessary.
9 kWEngine starts hard and runs rough.
10 kWAuto/Off/Manual switch is set to OFF, but the engine continues to run.
11 kWThere is no AC output from the generator.Reset circuit breaker to ON (or closed).
12 kWThere is no transfer to standby after utility source failure.

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing. Full Generac Number troubleshooting guide (8 entries) →

Parts

6model family
Part #DescriptionQtySystem
0GD1CPL (2006) (20KW)Service part / kit Amazon
0GD2CPL (30KW)Service part / kit Amazon
0KD1CPL (2006) (20KW)Service part / kit Amazon
0KD2CPL (30KW)Service part / kit Amazon
18AD1HI EFF (18KW)Service part / kit Amazon
67666REV_GService part / kit buy

Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Available documents

Reference — 0F5097 (1) (Generac)Reference — 0F6867 (Generac)Owner's manual — C8840 (Generac)Owner's manual — generac-xg04045anac-owners-manual (Generac)Parts manual — 0E1151 (Generac)Parts manual — 0E6304 (Generac)Parts manual — 0E8012 (1) (Generac)Parts manual — 0G0238A (Generac)Parts manual — 0G5244 (Generac)Parts manual — E1151Rev0 Sec1 (Generac)Parts manual — owners manual (Generac)
Full service, cheapest listings

Priced items from this model's own parts manual.

Air filter 140-1347$100.60
1 priced item$100.60