HomeGeneracGenerac MD600

Generac MD600 Generator Set

The Generac MD600 is a 600 kW (1765 kVA) Diesel standby generator set powered by a Generac P222LE engine. It is available at 277/480 V, 3-phase, 60 Hz and rated 903 A. It holds about 42 L (11.1 gal) of oil and 131 L (34.6 gal) of coolant, with a maximum ambient rating of 43.4 °C. Starting uses 2 group-2 batteries rated 1155 CCA at 24 V. The set measures 7598×5710×8410 mm (299.1×224.8×331.1 in), weighs about 9420 kg (20768 lb) and produces 8 dBA at 23 m.

600 kW
Standby
22.0 L
Displacement
42.0 L
Oil capacity
2
Document types

How to read your Generac serial & model number →

Typical fuel consumption for 600–605 kW Diesel generators →

Compare with other 600–605 kW Diesel generators →

Specifications

FuelDiesel
Frequency60.0 Hz
Standby power600 kW
Standby kVA1765
Prime power525 kW
EmissionsStationary Emergency
ControllerPower Manager System, PowerManager Generator
Oil capacity42.0 L
AlternatorMarathon 572RSL4028
Voltage options277/480 V
Phase3
Rated current903 A
Power factor0.8
Circuit breaker1000 A
Battery group2 x 12V
Battery cranking1155 CCA
Battery voltage24 V
Battery quantity2
Coolant capacity131 L
Max ambient43.4 °C
Dimensions (L×W×H)7598×5710×8410 mm
Dry weight9420 kg

Engine

Generac P222LE
Oil capacity42.0 L
Coolant capacity36.0 L
Displacement22.0 L
AspirationTurbocharged/Aftercooled
Rated speed1800 rpm

Common questions

What is the power rating of the Generac MD600?

The Generac MD600 is rated 600 kW standby (1765.0 kVA).

What engine does the Generac MD600 use?

The Generac MD600 is powered by the Generac P222LE engine.

What kind of fuel does the Generac MD600 run on?

The Generac MD600 runs on Diesel.

What's the oil capacity on a Generac MD600?

The Generac P222LE engine in the Generac MD600 has an oil capacity of 42.0 liters.

What alternator does the Generac MD600 use?

The Generac MD600 uses a Marathon 572RSL4028 alternator.

Fuel consumption

RatingLoadL/hgal/h
Prime25%14.153.43
Prime50%21.179.1
Prime75%32.3122.4
Prime100%42.1159.6
Prime130%8.833.0
Prime260%17.767.0
Prime395%26.599.0
Prime525%35.3131.0
Standby40.4149.0
Standby25%69.718.4
Standby50%88.728.2
Standby75%134.835.6
Standby100%156.741.4
Standby150%10.139.0
Standby300%20.278.0
Standby450%30.3115.0

Available documents

Spec sheet — 0184720SBY (Generac)Reference — 0165270SBY (Generac)Reference — 0168810SBY (Generac)Reference — 0179860SBY (Generac)Reference — 0179860sby-stockton-water-case-study (Generac)Reference — 0197230sby-a-md600-18-1l-perkins (Generac)Reference — Generac-Industrial-Power Case-Study Stockton-California-Wastewater-Treatment-Facility (Generac)