Specifications
| Fuel | Natural Gas, Propane Vapor |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 70 kW |
| Standby kVA | 88 |
| Prime power | 63 kW |
| Emissions | EPA Certified |
| Controller | Digital H Control Panel - Dual 4x20 Display |
| Oil capacity | 5.7 L |
| Alternator | 390 (Class NEMA MG1-32.6, NEMA MG1-1.66 insulation) |
| Voltage options | 120/208 V, 120/240 V, 277/480 V, 346/600 V |
| Phase | Three-Phase |
| Rated current | 267 A |
| Power factor | 0.8 |
| Circuit breaker | 267 A |
| Battery group | See Battery Index 0161970SBY |
| Battery voltage | 12 VDC V |
| Battery quantity | 1 |
| Coolant capacity | 23.9 L |
| Max ambient | 40 °C |
| Dimensions (L×W×H) | 2360×1015×1914 mm |
| Dry weight | 875 kg |
| Tank runtime | N/A hr |
Engine
| Oil capacity | 5.7 L |
|---|---|
| Coolant capacity | 23.9 L |
| Displacement | 6.8 L |
| Aspiration | Naturally Aspirated |
| Rated speed | 1800 rpm |
Common questions
How many kW is the Generac G70LG2?
The Generac G70LG2 is rated 70 kW standby (88.0 kVA).
What engine does the Generac G70LG2 use?
The Generac G70LG2 is powered by the Generac G70LG2 engine.
What fuel does the Generac G70LG2 use?
The Generac G70LG2 runs on Natural Gas, Propane Vapor.
How much oil does the Generac G70LG2 take?
The Generac G70LG2 engine in the Generac G70LG2 has an oil capacity of 5.7 liters.
What is the cooling system capacity of the Generac G70LG2?
The Generac G70LG2 cooling system holds 23.9 liters (6.3 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the continuous rating of the Generac G70LG2?
The Generac G70LG2 is rated 63 kW prime (79 kVA), against 70 kW standby.
What is the dry weight of the Generac G70LG2?
The Generac G70LG2 has a dry weight of 875 kg (1929 lb).
What voltages is the Generac G70LG2 available in?
The Generac G70LG2 is offered in 120/208 V, 120/240 V, 277/480 V, 346/600 V, Three-Phase-phase.
How many cold cranking amps does the Generac G70LG2 require?
The Generac G70LG2 uses 1 battery, 12 VDC V each, group See Battery Index 0161970SBY, per the manufacturer specification sheet.
Which alternator is fitted to the Generac G70LG2?
The Generac G70LG2 uses a 390 alternator. Insulation class NEMA MG1-32.6, NEMA MG1-1.66.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Standby | 100% | 1009.0 | 28.6 |
Available documents
This page was generated from the 1 manufacturer document above by automated extraction; every figure shown is copied from one of them. How the data is compiled.