Doosan G30-SIIIA Generator Set

The Doosan G30-SIIIA is a 26 kW (89.8 kVA) Diesel standby generator set powered by a Doosan G30-SIIIA engine. It is available at 230 V and 400 V, 3-phase, 50 Hz and rated 80 A. It holds about 4.5 L (1.2 gal) of oil and 4.5 L (1.2 gal) of coolant, with a maximum ambient rating of 40 °C. Starting uses 1 group-35 battery rated 550 CCA at 12 V. The set measures 1250×750×750 mm (49.2×29.5×29.5 in), weighs about 250 kg (551 lb) and produces 76 dBA at 7 m. An integrated tank holds 15 L (4.0 gal), roughly 5 hours of runtime.

26 kW
Standby
2.5 L
Displacement
4.5 L
Oil capacity
1
Document types

How to read your Doosan serial & model number →

Typical fuel consumption for 25–30 kW Diesel generators →

Compare with other 25–30 kW Diesel generators →

Specifications

FuelDiesel
Frequency50.0 Hz
Standby power26 kW
Standby kVA89
Prime power26 kW
EmissionsStage IIIA
ControllerNot specified
Oil capacity4.5 L
AlternatorG30-SIIIA
Voltage options230 V, 400 V
Phase3
Rated current80 A
Power factor0.8
Circuit breaker125 A
Battery group35
Battery cranking550 CCA
Battery voltage12 V
Battery quantity1
Coolant capacity4.5 L
Max ambient40 °C
Dimensions (L×W×H)1250×750×750 mm
Dry weight250 kg
Sound level76.0 dBA @ 7 m
Fuel tank15.0 L
Tank runtime5 hr

Engine

Doosan G30-SIIIA
Oil capacity4.5 L
Coolant capacity4.5 L
Displacement2.5 L
AspirationTurbocharged
Rated speed2500 rpm

Filters & service parts

model family
ItemSpecCapacityPart #Interval
Air filterAir filter—
Fuel filterFuel filter—
BatteryBattery—
BeltFan belt—
CoolantCoolant4.0 litre—1 hr
OilEngine oil10.0 litres—100 hr

Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.

Common questions

What size generator is the Doosan G30-SIIIA?

The Doosan G30-SIIIA is rated 26 kW standby (89.8 kVA).

What engine does the Doosan G30-SIIIA use?

The Doosan G30-SIIIA is powered by the Doosan G30-SIIIA engine.

Is the Doosan G30-SIIIA diesel or gas?

The Doosan G30-SIIIA runs on Diesel.

What is the oil capacity of the Doosan G30-SIIIA?

The Doosan G30-SIIIA engine in the Doosan G30-SIIIA has an oil capacity of 4.5 liters.

What is the coolant capacity of the Doosan G30-SIIIA?

The Doosan G30-SIIIA cooling system holds 4.5 liters (1.2 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

How loud is the Doosan G30-SIIIA?

The Doosan G30-SIIIA is rated at 76.0 dBA at 7 m, per the manufacturer specification sheet.

What is the dry weight of the Doosan G30-SIIIA?

The Doosan G30-SIIIA has a dry weight of 250 kg (551 lb).

What size fuel tank does the Doosan G30-SIIIA have?

The Doosan G30-SIIIA has a 15 liter (4 US gallon) fuel tank, giving about 5 hours of runtime.

What voltage does the Doosan G30-SIIIA produce?

The Doosan G30-SIIIA is offered in 230 V, 400 V, 3-phase.

How many cold cranking amps does the Doosan G30-SIIIA require?

The Doosan G30-SIIIA uses 1 battery, 12 V each, 550 CCA, group 35, per the manufacturer specification sheet.

What alternator comes on the Doosan G30-SIIIA?

The Doosan G30-SIIIA uses a G30-SIIIA alternator.

Troubleshooting

6

Symptoms & remedies

SymptomRemedy
Engine runs but generator will not take loadCheck Warm up timer has timed out. Ensure generator load inhibit signal is not present on the module inputs. Check connections to the switching device.
Incorrect reading on Engine gaugesFail to stop alarm when engine is at rest Check engine is operating correctly. Check that sensor is compatible with the module and that the module configuration is suited to the sensor.
CAN ECU WARNING CAN ECU SHUTDOWNThis indicates a fault condition detected by the engine ECU and transmitted to the DSE controller.
CAN DATA FAILIndicates failure of the CAN data link to the engine ECU. Check all wiring and termination resistors (if required).
Inaccurate generator measurements on controller displayCheck that the CT primary, CT secondary and VT ratio settings are correct for the application. Check that the CTs are wired correctly with regards to the direction of current flow (pt, p2 and s1, s2) and additionally ensure that CTs are connected to the correct phase (errors will occur if CT1 is connected to phase 2). Remember to consider the power factor (kW = kVA x powerfactor). The controller is true RMS measuring so gives more accurate display when compared with an 'averaging' meter such as an analogue panel meter or some lower specified digital multimeters. Accuracy of the controller is better than 1% of full scale. Generator voltage full scale is 415V ph-N, accuracy is ±4,15V (1% of 415V).
Module appears to 'revert' to an earlier configurationWhen editing a configuration using the PC software it is vital that the configuration is first 'read' from the controller before editing it. This edited configuration must then be 'written' back to the controller for the changes to take effect. When editing a configuration using the fascia editor, be sure to press the Auto Mode button to save the change before moving to another item or exiting the fascia editor.

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing. Full Doosan G30-SIIIA troubleshooting guide (15 entries) →

Available documents

Owner's manual — 46674960-C-EN-02-18-OM-G20-30-40-SIIIA (Doosan)

This page was generated from the 1 manufacturer document above by automated extraction; every figure shown is copied from one of them. How the data is compiled.