Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 50.0 Hz |
| Standby power | 96 kW |
| Standby kVA | 205 |
| Prime power | 97 kW |
| Emissions | Stage IIIA |
| Controller | Not specified |
| Oil capacity | 16.0 L |
| Alternator | G250 |
| Voltage options | 230 V, 400 V |
| Phase | 3 |
| Rated current | 200 A |
| Power factor | 0.8 |
| Circuit breaker | 450 A |
| Battery group | 35 |
| Battery cranking | 550 CCA |
| Battery voltage | 12 V |
| Battery quantity | 1 |
| Coolant capacity | 16.0 L |
| Max ambient | 40 °C |
| Dimensions (L×W×H) | 1950×1450×1450 mm |
| Dry weight | 760 kg |
| Sound level | 83.0 dBA @ 7 m |
| Fuel tank | 15.0 L |
| Tank runtime | 5 hr |
Engine
| Oil capacity | 16.0 L |
|---|---|
| Coolant capacity | 16.0 L |
| Displacement | 6.0 L |
| Aspiration | Turbocharged |
| Rated speed | 2500 rpm |
Filters & service parts
model family| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | Air filter | — | |||
| Fuel filter | Fuel filter | — | |||
| Battery | Battery | — | |||
| Belt | Fan belt | — | |||
| Coolant | Coolant | 4.0 litre | — | 1 hr | |
| Oil | Engine oil | 10.0 litres | — | 100 hr |
Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.
Common questions
What is the power rating of the Doosan G250?
The Doosan G250 is rated 96 kW standby (205.0 kVA).
Which engine powers the Doosan G250?
The Doosan G250 is powered by the Doosan G250 engine.
What fuel does the Doosan G250 use?
The Doosan G250 runs on Diesel.
What is the oil capacity of the Doosan G250?
The Doosan G250 engine in the Doosan G250 has an oil capacity of 16.0 liters.
What is the cooling system capacity of the Doosan G250?
The Doosan G250 cooling system holds 16 liters (4.2 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the prime power rating of the Doosan G250?
The Doosan G250 is rated 97 kW prime (205 kVA), against 96 kW standby.
What is the sound level of the Doosan G250?
The Doosan G250 is rated at 83.0 dBA at 7 m, per the manufacturer specification sheet.
What is the dry weight of the Doosan G250?
The Doosan G250 has a dry weight of 760 kg (1675 lb).
What size fuel tank does the Doosan G250 have?
The Doosan G250 has a 15 liter (4 US gallon) fuel tank, giving about 5 hours of runtime.
What voltage does the Doosan G250 produce?
The Doosan G250 is offered in 230 V, 400 V, 3-phase.
How many cold cranking amps does the Doosan G250 require?
The Doosan G250 uses 1 battery, 12 V each, 550 CCA, group 35, per the manufacturer specification sheet.
Which alternator is fitted to the Doosan G250?
The Doosan G250 uses a G250 alternator.
Troubleshooting
6Symptoms & remedies
| Symptom | Remedy |
|---|---|
| Engine runs but generator will not take load | Check Warm up timer has timed out. Ensure generator load inhibit signal is not present on the module inputs. Check connections to the switching device. |
| Incorrect reading on Engine gauges | Fail to stop alarm when engine is at rest Check engine is operating correctly. Check that sensor is compatible with the module and that the module configuration is suited to the sensor. |
| CAN ECU WARNING CAN ECU SHUTDOWN | This indicates a fault condition detected by the engine ECU and transmitted to the DSE controller. |
| CAN DATA FAIL | Indicates failure of the CAN data link to the engine ECU. Check all wiring and termination resistors (if required). |
| Inaccurate generator measurements on controller display | Check that the CT primary, CT secondary and VT ratio settings are correct for the application. Check that the CTs are wired correctly with regards to the direction of current flow (pt, p2 and s1, s2) and additionally ensure that CTs are connected to the correct phase (errors will occur if CT1 is connected to phase 2). Remember to consider the power factor (kW = kVA x powerfactor). The controller is true RMS measuring so gives more accurate display when compared with an 'averaging' meter such as an analogue panel meter or some lower specified digital multimeters. Accuracy of the controller is better than 1% of full scale. Generator voltage full scale is 415V ph-N, accuracy is ±4,15V (1% of 415V). |
| Module appears to 'revert' to an earlier configuration | When editing a configuration using the PC software it is vital that the configuration is first 'read' from the controller before editing it. This edited configuration must then be 'written' back to the controller for the changes to take effect. When editing a configuration using the fascia editor, be sure to press the Auto Mode button to save the change before moving to another item or exiting the fascia editor. |
Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing. Full Doosan G250 troubleshooting guide (15 entries) →