Home›Cummins/Onan›Cummins/Onan PCC1301 - Rental Sets

Cummins/Onan PCC1301 - Rental Sets Generator Set

The Cummins/Onan PCC1301 - Rental Sets is a generator set.

1
Document types

How to read your Cummins/Onan serial & model number →

Service parts for the PCC1301 - Rental Sets

Grouped by system, with how many of each the parts manual calls for.

Air intake

1 required
0908-0123Air filtersee priceAmazon

Fuel system

1 required
0908-0125Fuel filtersee priceAmazon

Oil system

1 required
0908-0124Oil filtersee priceAmazon

Belts

1 required
0908-0127Beltsee priceAmazon

Cooling system

1 required
0908-0126Coolant filtersee priceAmazon

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

ControllerPowerCommand 1301

Maintenance & consumables

ItemSpecCapacityPart #Interval
Air filterAir Filter0908-0123 Amazon eBay
Fuel filterFuel Filter0908-0125 Amazon eBay
Oil filterOil Filter0908-0124 Amazon eBay
BeltBelt0908-0127 Amazon eBay
Coolant filterCoolant Filter0908-0126 Amazon eBay

Common questions

What oil filter fits the Cummins/Onan PCC1301 - Rental Sets?

The Cummins/Onan PCC1301 - Rental Sets uses oil filter part number 0908-0124.

Which fuel filter part number does the Cummins/Onan PCC1301 - Rental Sets take?

The Cummins/Onan PCC1301 - Rental Sets uses fuel filter part number 0908-0125.

What air filter does the Cummins/Onan PCC1301 - Rental Sets use?

The Cummins/Onan PCC1301 - Rental Sets uses air filter part number 0908-0123.

Troubleshooting

41

Fault codes

CodeMeaningCauseRemedy
1HIGH COOLANT TEMP — Shutdown; indicates that the engine coolant temperature is above normal and has reached the Shutdown trip point
2LOW OIL PRESSURE — Shutdown; indicates the engine oil pressure has dropped below normal and has reached the Shutdown trip point
12HIGH AC VOLTAGE — Shutdown; indicates that one or more measured AC output voltages have exceeded the threshold for longer than a specified time limit. The threshold and time limits are 130% of nominal for zero seconds or 110% of nominal for ten seconds
13LOW AC VOLTAGE — Shutdown; indicates that the measured AC output voltage is below the threshold for longer than a specified time limit. The threshold and time limits are 85% of nominal for ten seconds
14OVER FREQUENCY — Shutdown; indicates that the alternator frequency is 6 Hertz above the governor reference
15UNDER FREQUENCY — Shutdown; indicates that the alternator frequency is 6 Hertz under the governor reference
27EXCITATION FAULT — Shutdown; indicates that a loss of voltage or frequency sensing from the generator has occurred
31OVERSPEED — Shutdown; indicates that the engine has exceeded normal operating speed. The default thresholds are 1725RPM (50Hz) or 2075RPM (60Hz)
38FIELD OVERLOAD — Shutdown; indicates that the Field AVR Duty Cycle has been at the maximum for at least fifteen seconds
45SPEED SIGNAL LOST — Shutdown; indicates that no magnetic pickup pulses are sensed for a Loss of Speed delay. If a magnetic pickup is not installed, then speed sensing is performed by monitoring AC line frequency
46HIGH AC CURRENT — Shutdown; indicates that alternator output current (one or more phases) has exceeded 150% of the rated output current continuously for more than ten seconds
61EMERGENCY STOP — Shutdown; indicates an Emergency Stop has been activated
71SPEED HZ MATCH — Shutdown; indicates that measured engine speed and measured alternator AC output frequency do not agree
72FAIL TO CRANK — Shutdown; the generator set has failed to sense rotation for two start attempts. This indicates a possible fault with the control, speed sensing, or the starting systemPossible fault with the control, speed sensing, or the starting system
73FAIL TO START — Shutdown; the system has failed to start after a set number of crank attempts. This indicates a possible fuel system problem (engine cranks but fails to start)Possible fuel system problem (engine cranks but fails to start)
74FAIL TO STOP — Shutdown; the generator set continues to run after receiving a shutdown command from the controller. This may indicate that the Battle Short feature has been enabledBattle Short feature has been enabled
75Customer Input 1 — Shutdown; the nature of the fault is an optional customer selection
76Customer Input 2 — Shutdown; the nature of the fault is an optional customer selection
77SHUTDOWN AFTER BS — Shutdown; a shutdown fault occurred while the Battle Short mode was enabled
150READY TO LOAD — the generator set is at rated voltage and frequency
153NOT IN AUTO — indicates that the PCC1301 control is not in the Auto mode
155COMMON ALARM — the control has detected a Warning or Shutdown fault
156COMMON WARNING — the control has detected a Warning fault
157COMMON SHUTDOWN — the control has detected a Shutdown fault
158Customer Input 1 — the nature of the fault is an optional customer selection
159Customer Input 2 — the nature of the fault is an optional customer selection
202PRE-HIGH COOLANT TEMP — Warning; indicates that the engine has begun to overheat and the engine coolant temperature has risen to an unacceptable level
203LOW COOLANT TEMP — Warning; indicates that the engine coolant temperature is below the adjusted setpoint. This may indicate that the coolant heater is not operating or is not circulating coolantCoolant heater is not operating or is not circulating coolant
204Customer Input 1 — Warning; the nature of the fault is an optional customer selection
205Customer Input 2 — Warning; the nature of the fault is an optional customer selection
212COOLANT SENSOR OOR — Warning; indicates the coolant temperature sensor output is out of range (OOR), high or low
213LOW BATTERY — Warning; indicates battery voltage supply to the control is approaching a low level at which unpredictable operation can occur
214HIGH BATTERY — Warning; indicates battery voltage supply to the control is approaching a high level at which damage to the control can occur
215PRE-LOW OIL PRESSURE — Warning; indicates that the engine oil pressure is approaching an unacceptable level
216HIGH AC CURRENT — Warning; indicates that the alternator output current (one or more phases) has exceeded 130% of nominal, or has exceeded 110% of nominal for 60 seconds
217OIL PRESS SENSOR OOR — Warning; indicates the oil pressure sensor output is out of range (OOR), high or low
218BATTLE SHORT ACTIVE — Warning; indicates that the control is in Battle Short mode – used to bypass several fault shutdowns for generator set operation during emergencies
219CHARGER FAILURE — Warning; indicates the battery charging alternator has not reached an acceptable voltage range within the selected time period (default = 120 seconds). This warning is also displayed if your alternator is a type that does not support the control's charging alternator logic functionalityBattery charging alternator has not reached an acceptable voltage range within the selected time period; alternator is a type that does not support the control's charging alternator logic functionalityIf the alternator does not support the control's charging alternator logic functionality, this warning can be disabled if the Charger Alt. Enable setting is set to "No"
220FAIL TO SHUTDOWN — Warning; indicates that a shutdown fault is active, but is being bypassed by Battle Short
221WEAK BATTERY — Warning; indicates that the generator set battery voltage is below battery thresholds during cranking
220Shutdown lamp remains lit even though the set continues to runOverridden shutdown fault occurs when Battle Short mode is enabledPress ▲, ▼ or ◄ button to acknowledge the fault

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Parts

7
Part #DescriptionQtySystem
0908-0123Air Filter1Air filter Amazon eBay
0908-0124Oil Filter1Oil filter Amazon eBay
0908-0125Fuel Filter1Fuel filter Amazon eBay
0908-0126Coolant Filter1Coolant filter Amazon eBay
0908-0127Belt1Belt Amazon eBay
0908-0128Battery1Battery Amazon eBay
0908-0129Spark Plug1Spark plug Amazon eBay

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Available documents

Service manual — 908-0118 Cummins Power Command Control 1301 Rental Manual (11-2009) (Cummins/Onan)

This page was generated from the 1 manufacturer document above by automated extraction; every figure shown is copied from one of them. How the data is compiled.